Algo 8039 Manuel utilisateur

8039 SIP Video Intercom (FW version 2.0.1)
8039 SIP Video Intercom
FW Version 2.0.1
Installation & Configuration
Order Codes
8039 SIP Video Intercom
Document 90-00075
11/27/2019
Page 1
Algo Communication Products Ltd
4500 Beedie St Burna y BC Canada V5J 5L2
www.algosolutions.com
(604) 454-3792

8039 SIP Video Intercom (FW version 2.0.1)
Table of Contents
IMPORTANT SAFETY INFORMATION......................................................................................................3
OVERVIEW................................................................................................................................................. 6
INTRODUCTION................................................................................................... 6
WHAT’S NEW (COMPARED TO THE PREVIOUS FIRMWARE V1.5)........................................6
SETUP AND INSTALLATION.....................................................................................................................
GETTING STARTED - QUICK INSTALL & TEST...............................................................
INSTALLATION.................................................................................................... 8
PROGRAMMING AND CONFIGURATION........................................................................8
WIRING CONNECTIONS.......................................................................................... 9
WEB INTERFACE STATUS AND LOGIN.................................................................................................11
WEB INTERFACE LOGIN.......................................................................................11
STATUS..........................................................................................................12
STATUS TAB – VIDEO.........................................................................................12
WEB INTERFACE BASIC SETTINGS......................................................................................................13
BASIC SETTINGS TAB – SIP..................................................................................13
BASIC SETTINGS TAB – FEATURES..........................................................................14
BASIC SETTINGS TAB – VIDEO...............................................................................16
BASIC SETTINGS TAB – KEYPAD............................................................................19
BASIC SETTINGS TAB – DOOR CONTROL..................................................................21
BASIC SETTINGS TAB – MULTICAST........................................................................23
WEB INTERFACE ADVANCED SETTINGS.............................................................................................26
ADVANCED SETTINGS TAB - NETWORK....................................................................26
ADVANCED SETTINGS TAB – ADMIN........................................................................28
ADVANCED SETTINGS TAB – TIME..........................................................................30
ADVANCED SETTINGS TAB – PROVISIONING..............................................................31
ADVANCED SETTINGS TAB – TONES........................................................................33
ADVANCED SETTINGS TAB – ADVANCED AUDIO..........................................................34
ADVANCED SETTINGS TAB – ADVANCED SIP.............................................................35
ADVANCED SETTINGS TAB – ADVANCED MULTICAST....................................................3
WEB INTERFACE SYSTEM..................................................................................................................... 39
SYSTEM TAB - MAINTENANCE...............................................................................39
UPGRADE 8039 SIP VIDEO INTERCOM FIRMWARE......................................................40
SYSTEM – SYSTEM LOG.......................................................................................40
SPECIFICATIONS..................................................................................................................................... 41
8061 IP RELAY CONTROLLER............................................................................................................... 42
TYPICAL 8039/8061 SETUP..................................................................................................................... 43
POE AND RELAY CONNECTIONS ON BACK OF 8061 IP RELAY CONTROLLER:......................43
CONFIGURING THE 8061........................................................................................................................ 44
FCC COMPLIANCE STATEMENT............................................................................................................45
Document 90-00075
11/27/2019
Page 2
Algo Communication Products Ltd
4500 Beedie St Burna y BC Canada V5J 5L2
www.algosolutions.com
(604) 454-3792

8039 SIP Video Intercom (FW version 2.0.1)
Important Safety Information
Important Safety Information
This product is powered y a certified limited power source (LPS), Power over
Ethernet (PoE); through CAT5 or CAT6 connection wiring to an IEEE 802.3af
compliant network PoE switch. The product is intended for installation indoors or
on outdoor perimeter of a uilding. If used in an outdoor environment, additional
protective measures must e taken according to the installation manual. All wiring
connections to the product must e in the same uilding. If the product is installed
eyond the uilding perimeter or used in an inter- uilding application, the wiring
connections must e protected against over voltage / transient. Algo recommends
that this product e installed y a qualified electrician.
If you are una le to understand the English language safety information then
please contact Algo y email for assistance efore attempting an installation
Consignes de Sécurité Importantes
Ce produit est alimenté par une source d’alimentation limitée certifiée
(alimentation par Ethernet); des câ les de catégorie 5 et 6 joignent un
commutateur réseau à alimentation par Ethernet homologué IEEE 802.3af. Le
produit est conçu pour être installé à l’intérieur ou dans une zone adjacente à un
édifice; selon le manuel d’installation, des mesures de sécurité additionnelles
s’avèrent alors nécessaires. Tout le câ lage rattaché au produit doit se trouver
dans le même édifice. Si le produit est installé au-delà du périmètre de l’édifice ou
utilisé pour plusieurs édifices, le câ lage doit être protégé des surtensions
transitoires. Algo recommande qu’un électricien qualifié se charge de l’installation
de ce produit.
Si vous ne pouvez comprendre les consignes de sécurité en anglais, veuillez
communiquer avec Algo par courriel avant d’entreprendre l’installation au
Información de Seguridad Importante
Este producto funciona con una fuente de alimentación limitada (Limited Power
Source, LPS) certificada, Alimentación a través de Ethernet (Power over Ethernet,
PoE); mediante un ca le de conexión CAT5 o CAT6 a un conmutador de red con
PoE en cumplimiento con IEEE 802.3af. El producto se de e instalar en lugares
cerrados o en el perímetro de un edificio al aire li re. Si se utiliza en un am iente
al aire li re, se de en tomar medidas de protección adicionales de acuerdo con el
Document 90-00075
11/27/2019
Page 3
Algo Communication Products Ltd
4500 Beedie St Burna y BC Canada V5J 5L2
www.algosolutions.com
(604) 454-3792

8039 SIP Video Intercom (FW version 2.0.1)
manual de instalación. Todas las conexiones ca leadas al producto de en estar
en el mismo edificio. Si el producto se instala fuera del perímetro del edificio o se
utiliza en una aplicación en varios edificios, las conexiones ca leadas se de en
proteger contra so retensión o corriente transitoria. Algo recomienda que la
instalación de este producto la realice un electricista calificado.
Si usted no puede comprender la información de seguridad en inglés,
comuníquese con Algo por correo electrónico para o tener asistencia antes de
intentar instalarlo: [email protected].
Wichtige Sicherheitsinformationen
Dieses Produkt wird durch eine zertifizierte Stromquelle mit egrenzter Leistung
(LPS – Limited Power Source) etrie en. Die Stromversorgung erfolgt ü er
Ethernet (PoE – Power over Ethernet). Dies geschieht durch eine Cat-5-
Ver indung oder eine Cat-6-Ver indung zu einer IEEE 802.3af-konformen
Ethernet-Netzwerkweiche. Das Produkt wurde konzipiert für die Installation
innerhal eines Ge äudes oder außerhal eines Ge äudes. Bei der Anwendung
außerhal eines Ge äudes müssen zusätzliche Schutzmaßnahmen gemäß der
Ge rauchsanweisung durchgeführt werden. Alle Ka elver indungen zum Produkt
müssen im sel en Ge äude estehen. Wenn das Produkt jenseits des Ge äudes
oder für mehrere Ge äude genutzt wird, müssen die Ka elver indungen vor
Ü erspannung und Spannungssprüngen geschützt werden. Algo empfiehlt das
Produkt von einem qualifizierten Elektriker installieren zu lassenv.
Sollten Sie die englischen Sicherheitsinformationen nicht verstehen, kontaktieren
Sie itte Algo per Email evor Sie mit der Installation eginnen, um Unterstützung
zu erhalten. Algo kann unter der folgenden E-Mail-Adresse erreicht werden:
安全须知
本产品由认证的受限电源(LPS),以太网供电(PoE),通过 CAT5 或 CAT6 路
联接至 IEEE 802.3af 兼容的 PoE 网络交换机供电。本产品适用于室内或建筑物周边
安装。如用于室外环境,必须按照安装手册采用附加的保护措施。所有联接本产品
的 路必须源自同一建筑物。本产品如需用于超出建筑物周边范围或跨建筑物的安
装, 路联接部分必须有过压和瞬态保护。Algo 建议本产品由专业电工安装。
如果您对理解英文版安全须知有问题,安装前请通过电子邮件和 Algo 联
Document 90-00075
11/27/2019
Page 4
Algo Communication Products Ltd
4500 Beedie St Burna y BC Canada V5J 5L2
www.algosolutions.com
(604) 454-3792

8039 SIP Video Intercom (FW version 2.0.1)
EMERGENCY COMMUNICATION
If used in an emergency communication application, the 8039 SIP Video Intercom
should e routinely tested. SNMP supervision is recommended for assurance of
proper operation. Contact Algo for other methods of operational assurance
including the use of the integrated microphone for automated “sound to air”
acoustic testing.
WET OR OUTDOOR ENVIRONMENTS
The 8039 SIP Video Intercom is intended for indoor or outdoor locations and may
e su jected to spray or weather, provided the rear wiring cavity is properly sealed
to prevent water ingress.
Gaskets included with the 8039 SIP Video Intercom may e effective against water
ingress on some, ut not all surfaces in which case additional protective measures
must e taken such as a perimeter sealant.
CAT5 or CAT6 connection wiring to an IEEE 802.3af compliant network PoE
switch must not leave the building perimeter without adequate lightning
protection.
When the Intercom is connected to wiring that exits the building, there is
potential risk of lightning induced electrical surges or high voltages from
fault conditions. To reduce risk, outdoor wiring should be protected by Earth
grounded conduit whenever possible. Relay input and output connections
must not leave the building perimeter without adequate lightning protection.
Document 90-00075
11/27/2019
Page 5
Algo Communication Products Ltd
4500 Beedie St Burna y BC Canada V5J 5L2
www.algosolutions.com
(604) 454-3792

8039 SIP Video Intercom (FW version 2.0.1)
Overview
Introduction
The 8039 SIP Video Intercom is ideal for secure usiness entrances, emergency
intercom, and gated entrances. The Algo 8039 provides hands-free intercom
capa ility with video, entrance security with door unlock control, rugged
weatherproof design, and superior audio performance.
Fully compati le with SIP industry standards, the 8039 SIP Video Intercom will
work with most hosted or enterprise SIP- ase servers supporting third-party SIP
endpoints.
The 8039 SIP Video Intercom is configured using central provisioning features or
y accessing a we interface using rowsers such as Google Chrome, Firefox, or
Internet Explorer.
What is Included
•8039 SIP Video Intercom
•Mounting Plate
What is not Included
•Optional 8061 IP Relay Controller
Document 90-00075
11/27/2019
Page 6
Algo Communication Products Ltd
4500 Beedie St Burna y BC Canada V5J 5L2
www.algosolutions.com
(604) 454-3792

8039 SIP Video Intercom (FW version 2.0.1)
Setup and Installation
Getting Started - Quick Install & Test
This guide provides important safety information which should be read thoroughly
before permanently installing the product.
1. Connect the 8039 SIP Video Intercom to an IEEE 802.3af compliant PoE network
switch. The acklight keypad will turn on. After a out 30 seconds, a eep will signal the
completion of the oot process.
2. After the oot is complete, press the call utton on the 8039 to hear the IP address.
(Once the SIP Server field is populated in the 8039 we interface, the call utton will
contact the preconfigured extension when pressed.) The IP address may also e
discovered y downloading the Algo locator tool to find Algo devices on your network:
www.algosolutions.com/locator
3. Access the 8039 SIP Video Intercom we page y entering the IP address into a
rowser (Chrome, IE, Firefox etc) and login using the default password algo .
4. Enter the IP address for the SIP server into the SIP Domain field under the BASIC
SETTINGS > SIP ta .
5. Enter the SIP Extension, Authentication ID, and Password. Also enter the target Dialing
Extension that the Intercom will call.
Note: The Authentication ID may also be called Username for some SI servers, and in
some cases may be the same as the SI extension.
6. Press the Call Button on the 8039 Intercom, then answer the phone to communicate
over the Intercom. Press the digit 6 on the phone keypad to activate the door control
relay for three seconds (if applica le).
Document 90-00075
11/27/2019
Page 7
Algo Communication Products Ltd
4500 Beedie St Burna y BC Canada V5J 5L2
www.algosolutions.com
(604) 454-3792

8039 SIP Video Intercom (FW version 2.0.1)
Installation
The 8039 SIP Video Intercom is
weather protected for outdoor
installation. However, if network
ca ling extends eyond the perimeter
of the uilding, then adequate lightning
protection is required to protect the
ca ling and network switch from
lightning surges. No lightning
protection is required y UL or CSA if
the 8039 is located on the outside wall
of a uilding and the wiring is inside
the perimeter of the uilding.
The 8039 is wall and door frame
(mullion) mounta le via the supplied
mounting plate:
Secure the mounting plate to the wall/
mullion door frame via two #8 screws.
Attach the 8039 into the mounting
plate and secure the device in place
with the attached security screw at the
ottom of the mounting plate using the
provided Allen wrench.
Programming and Configuration
The 8039 SIP Video Intercom is configura le using the we interface or
provisioning features.
After oot up, the speaker will eep and the intercom will have o tained an IP
address. If there is no DHCP server the 8039 SIP Video Intercom will default to the
static IP address 192.168.1.111.
Before the 8039 is configured, the call utton on the front can e pressed to play
the IP address over the speaker. (Once the SIP Server field is populated on the
8039 we interface, the call utton will contact the preconfigured extension when
pressed.) The IP address may e discovered y downloading the Algo locator tool
to find Algo devices on your network: www.algosolutions.com/locator
Document 90-00075
11/27/2019
Page 8
Algo Communication Products Ltd
4500 Beedie St Burna y BC Canada V5J 5L2
www.algosolutions.com
(604) 454-3792

8039 SIP Video Intercom (FW version 2.0.1)
Enter the IP address (e.g 192.168.1.111) into a rowser such as Google Chrome,
Firefox, or Internet Explorer (other than IE9). The we interface should e visi le
and the default password will e algo in lower case letters.
Wiring Connections
Network Connection
The speaker provides a RJ45 jack for network
connection. A ca le run from the switch can e
terminated to a modular jack with connection y patch
cord, or terminated with a RJ45 plug.
PoE (Power over Ethernet) must e 48V 350 mA IEEE
802.3af compliant whether provided y the network
switch or injector.
There are two lights on the Ethernet jack:
Green light: On when Ethernet is working, flickers off
to indicate activity on the port.
Amber light: Off when successful 100M ps link is
esta lished. Typically on only riefly at power up.
Under normal conditions, the Am er light will turn on
immediately after the Ethernet ca le is first connected.
This indicates that PoE power has een successfully
applied. Once the device connects to the network, it
will switch to the Green light instead, which will
typically flicker indicating traffic on the network.
Door Control Relay
Provides oth normally open and normally closed
relay contacts. Note: The 8061 I Relay Controller
can be used as an alternative more secure option
for door opening control, by using a separate relay
from the public-facing intercom.
Serial Control
**Reserved for future use**
Door Sensor (Dry Contact Input)
An external call utton can e connected as a normally open switch. When the
relay is triggered, this will dial the pre-configured “Extension to Dial”.
Document 90-00075
11/27/2019
Page 9
Algo Communication Products Ltd
4500 Beedie St Burna y BC Canada V5J 5L2
www.algosolutions.com
(604) 454-3792

8039 SIP Video Intercom (FW version 2.0.1)
Backlit Keypad and Call Button
The acklit keypad and call utton will e steady during power up and will flash
during a reset.
If ena led, when making a call, the call utton light will flash rapidly, while the call
is ringing at the far-end phone. Once the call is answered, the flashing will slow
down.
Reset
The 8039 SIP Video Intercom can only e reset during a power up. To return all
the settings to the factory default for the 8039, wait until all the acklit keys start
flashing. Then press and hold the call utton until the call utton acklight
egins a dou le flash pattern. Release the call utton and allow the unit to
complete its oot process. Do not press the call button until all the keys
start flashing.
A reset will set all configuration options to factory default including the password.
Document 90-00075
11/27/2019
Page 10
Algo Communication Products Ltd
4500 Beedie St Burna y BC Canada V5J 5L2
www.algosolutions.com
(604) 454-3792
Autres manuels pour 8039
1
Table des matières
Autres manuels Algo Système d'interphone

Algo
Algo 3226 Manuel utilisateur

Algo
Algo 8036 Manuel utilisateur

Algo
Algo 3006 Manuel utilisateur

Algo
Algo 8039 Manuel utilisateur

Algo
Algo 8028 Manuel utilisateur

Algo
Algo 8201 Manuel utilisateur

Algo
Algo 8028 Manuel utilisateur

Algo
Algo 8036 Manuel utilisateur

Algo
Algo 3228 Station Port FXS Manuel utilisateur

Algo
Algo 8036 Manuel utilisateur






















