Airo UV 1500 Manuel

Model
UV 1500
Retain this manual for future reference.
UV2012E-S
By Hearth and Home Dynamics, LLC
SPACE HEATER & FAN
User’s Manual and Operating
Instructions
3-in-1
UV-C AIR SANITIZING

2
UV Air Sanitizer User Manual
Table of Contents
Specifications
Specifications ........................................................................................................................................................................................ 2
Safety Information ..............................................................................................................................................................................3
Product Identification ........................................................................................................................................................................ 5
Features .................................................................................................................................................................................................. 5
Placement for Use................................................................................................................................................................................ 6
Operation ................................................................................................................................................................................................6
Care and Maintenance ...................................................................................................................................................................... 8
Troubleshooting Guide ....................................................................................................................................................................10
Limited Warranty ................................................................................................................................................................................11
MODEL NUMBER: UV1500
DIMENSIONS: 14.6”L x 11.4”W x 14.6”H
WEIGHT: 16.5 pounds
INPUT VOLTAGE: 120V 60H 1500W
AIR SANITIZING OVERAGE: 160 sq. ft.
HEATING OVERAGE: 600 sq. ft.
UVC LAMP: 14W, 254nm Wavelength
REPLACEMENT UVC LAMP: UV150L
REPLACEMENT FILTER: UV150F

3
UV Air Sanitizer User Manual
Safety Information
READ AND SAVE THESE INSTRUCTIONS
WARNINGS
Failure to comply with the warnings listed below
may result in electric shock or serious injury.
• Read all instructions before using appliance.
•
•
To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet.
•
•This appliance is not intended for use in bathrooms, laundry areas and similar indoor locations. Never
locate appliance where it may fall into a bathtub or other water container.
•Always unplug the air sanitizer before moving it, opening the grill, changing filters, cleaning or whenever
the air sanitizer is not in use. Be sure to disconnect by the plug and not the cord.
•Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an
electric shock or fire, or damage the heater.
•Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do
not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be
tripped over.
•
•Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions, has
been dropped or damaged in any manner. Call Customer Service for assistance.
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire,
electric shock and injury to persons, including the following
•Use appliance only for intended household use as described in this manual. Any other use not
recommended by the manufacturer may cause fire, electric shock or injury to persons.
•To prevent a possible fire, do not block air intakes or exhaust in any manner.
Extreme caution is necessary when any heater is used by or near children or invalids and whenever
the heater is left operating and unattended.
• DO NOT use outdoors.
To disconnect appliance, switch controls off, then remove plug from outlet.
A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or
flammable liquids are used or stored.
•Always plug heaters directly into a wall outlet/receptacle. Never use with an extension cord or relocatable
power tap (outlet/power strip).

4
UV Air Sanitizer User Manual
Safety Information (cont.)
•
WARNING: This product can expose you to chemicals including lead or lead compounds, which are known
to the state of California to cause cancer and birth defects or other reproductive harm. For more information
go to www.P65Warnings.ca.gov.
Do not attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void
your warranty. The inside of the unit contains no user serviceable parts. All servicing should be
performed by qualified personnel only.
•WARNING: Skin or eye damage may result from directly viewing the light produced by the lamp in this
apparatus. Always disconnect power before replacing lamp or servicing. Replace Lamp with Lamp Model
No. AP150UB only.
"SAVE THESE INSTRUCTIONS"

5
Product Identification
FILTER
The lter captures large dust particles and allergen particles which helps extend the
life of your air sanitizer. The activated carbon absorbs formaldehyde, benzene, household and pet
odors.
The power of UV-C light sterilizes micro-organisms, such as germs, viruses, bacteria, and fungi (such
as mold toxins). The 254nm wavelength UV-C light damages the DNA or RNA of viruses, bacteria and
other pathogens and causes micro-organisms to lose the ability to multiply and cause disease.
For maxiand heat the area.
peration modes Timer, and Temperature Settings.
MICATHERMIC HEATING ELEMENT
GERMICIDAL UV-C LIGHT
Filter
Screen Frame
Filter
Power Cord
Wrap
Main
Power Switch
Handheld
Remote
Wheels
UV-C Lamp
Access Plate
UV-C
Lamp
Control
Panel
Air
Outlet
Power
Cord

6
UV Air Sanitizer User Manual
Placement for Use
2.Place 3-in-1 air sanitizer upright when using to ensure normal running.
3. Place 3-in-1 air sanitizer in populated areas to effectively improve the indoor air quality.
1.Do not place the 3-in-1 air sanitizer near curtains to avoid and prevent the curtain being
drawn into the sanitizer and damaging it.
Notice: Check the filter before using. Do not use this product if the filter is damaged.
Replace filter if there are cracks or holes in the filter.
The air sanitizer is recommended for use in a single, closed room up to 165 square feet
and the heating function comfortably heats up to 600 square feet.
Operation
Press the ON/OFF button to switch on the air sanitizer, press again to shut off
the air sanitizer.
Fan Only
UV Air Sanitizing
Press the UV FAN button to switch on the UV-C lamp to effectively kill bacteria in
the air. Note, the blue light behind the grille is not the UV-C wavelength. The UV-
C lamp is contained in the bottom of the product. The light behind the grille is
LED to indicate the product is in air sanitizing mode.
The Main Power Switch is located on the back of the Air Sanitizer near the power
cord. When the Main Power Switch is turned on there will be a prompt sound,
and the red light under the ON/OFF button will be on, indicating there is power
to the control panel.
Press UV FAN button once and the blue LED indicator light under UV comes on
and the display shows U1 (low fan speed), press the UV FAN button a second
time and the display shows U2 (high fan speed).
Press UV FAN button a three times and the blue LED indicator light under FAN
comes on or press the FAN button on the remote and the display shows F1 (low
fan speed), press the UV FAN button a fourth time or the FAN button a second
time on the remote and the display shows F2 (high fan speed).
Press UV FAN button a fifth time to shut off the fan.
Main Power Switch
ON/OFF Button

7
UV Air Sanitizer User Manual
Operation (cont.)
Shut Off Timer
Press TIMER button once for each hour increment between 1 to 12 hours to set
the countdown timer to shut off either the UV and/or Heating function. The
display will show the hour(s) selected. An amber LED light will indicate the timer
function has been set.
Heating
Press HEAT button once and a red LED indicator light comes on and the display
shows H1 for Low Heat (Note: High fan speed is default), press the HEAT button
a second time and the display shows H2 for Maximum Heat.
Setting Temperature
The heater temperature can be set between 60°F to 90°F (16°C to 32°C). The
temperature display can be changed between °F and °C by pressing the TEMP+
and TEMP- at the same time for 3 seconds.
Press TEMP+ to increase the temperature setting and TEMP- to decrease the
temperature setting.
Note: When the heater is on, the LED light behind the grille will be red to
indicate the product is in heating mode. If the UV function is on at the same time
as heating, the LED light behind the grille will be purple.
Press HEAT button a third time to shut off heat.
Note, the fan will continue to run for 1 minute to dissipate the heat within the product.
Shut Off Heat
There is a memory feature which will keep the previous settings when the product is turned on again.

8
UV Air Sanitizer User Manual
Care and Maintenance
It is not recommended to use the air sanitizer in places where candle soot or fireplace soot and smoke is
present. If candle or fireplace soot and smoke are present, then more frequent cleaning will be required.
Cleaning and Replacing Filter, Replacement Filter No.: UV150F
For optimal performance, the filter should be cleaned at least once every month. More frequent cleaning
may be required depending on the environmental conditions where you live.
Cleaning Filter
Use the brush attachment on your vacuum cleaner to remove lint and dirt from the filter. If necessary, you
can wash the filter in warm water with a mild dish detergent.
1. The Filter is located in the back of the Air Sanitizer, Fig. 3.
2. Remove the screw securing the Filter Screen Frame and slide Screen Frame out. The Filter will be
contained within the Screen Frame, Fig. 3&4.
3. Pull Filter from Screen Frame to clean or replace. The Filter is meant to fit snug within the Screen
Frame.
Screw the Screen Frame back into place securely.
4.
Fig. 4
Fig. 3
WARNING: Always disconnect power before attempting service or cleaning to reduce the risk of fire, electrical
shock or personal injury.
Attention: It is recommended to wear gloves when replacing the filter to avoid contact with
pollutants and replacing the UV-C lamp to prevent oils from your hand on the lamp.
CAUTION: Never operate the unit without a filter or with a damaged filter.

9
UV Air Sanitizer User Manual
1. Remove Bottom Access Plate by removing the four philips head screws, Fig. 5.
2. Remove the screw securing the UVC Lamp Holder and carefully unplug UVC Lamp, Fig. 6.
3. Carefully plug in the new UVC Lamp and resecure the Lamp Holder.
Replacing UVC Lamp, Replacement Lamp No.: UV150L
Attention: Follow all precautions identified in UVC
replacement lamp instructions.
Screw the Bottom Access Cover back into place securely.
4.
Fig. 6
Fig. 5
Care and Maintenance (cont.)
Unplug the unit before replacing UVC Lamp.
The UV lamp functions up to 12 months (8,000 hours) of continuous, effective operation. After 8,000 hours,
the lamp may remain illuminated, but its effectiveness greatly reduced. For maximum germicidal
protection, replace the UV lamp annually.
WARNING: UV Light is harmful to bare skin and eyes and can cause temporary or permanent loss of vision.
Never look directly at the UV lamp while it is illuminated-doing so could cause loss of vision!
CAUTION: Do not touch the glass part of the lamp. Oil from fingertips will decrease the effectiveness of the
lamp.

10
UV Air Sanitizer User Manual
Troubleshooting Guide
Common problem Possible cause Solutions
Unit does not
operate
1 The power switch is not turned on.
2 Not plugged in.
1 Turn the power switch in the back on
and press the power ON button to
turn on the sanitizer.
Airflow reduced or
sanitizing effect is
unsatisfied
1 Air inlet or air outlet is blocked.
2 Filter may be blocked.
1 Make sure the air inlet and outlet are
not blocked.
Care and Maintenance (cont.)
Cleaning the 3-in-1 Air Sanitizer Cabinet
Always unplug the unit before cleaning.
Clean outer surface with slightly dampened towel with a light water and dishwashing soap solution.
Do not allow water to enter the Air Sanitizer, this could damage the Air Sanitizer and/or cause electric shock.
•
•
•
Make sure the Air Sanitizer is completely dry before using.
•
Customer Service
If you did not find the solution to your problem or have a product question, contact our customer service at:
2 Check that the power cord is plugged
in to a properly grounded outlet.
2 Check and clean or replace the filter
if necessary.
Increase in noise
level
1 Air inlet or air outlet is blocked.
2 Filter may be blocked with lint,
dust or pet hair.
1 Make sure the air inlet and outlet are
not blocked.
2 Check and clean or replace the filter
if necessary.
Table des matières
Langues :
Autres manuels Airo Chauffage
Manuels Chauffage populaires d'autres marques

oventrop
oventrop Regucor Series Manuel utilisateur

Blaze King
Blaze King CLARITY CL2118.IPI.1 Manuel utilisateur

ELMEKO
ELMEKO ML 150 Manuel utilisateur

BN Thermic
BN Thermic 830T Manuel utilisateur

KING
KING K Series Mode d’emploi

Empire Comfort Systems
Empire Comfort Systems RH-50-5 Guide de démarrage rapide

Empire Heating Systems
Empire Heating Systems WCC65 Manuel utilisateur

Wetekom
Wetekom 92 86 43 Manuel utilisateur

Desa
Desa SPC170-F Manuel utilisateur

Watlow
Watlow Watrod Electric Tubular Heaters Manuel utilisateur

Haverland
Haverland ECO-DRY GPS Series Manuel de la liste des pièces

Stelpro
Stelpro ASILVC2060 Series Manuel utilisateur