Airius DIAMOND Series Manuel utilisateur

www.airius.com.au
PRODUCT INFORMATION &
INSTALLATION GUIDE 2021
Airius Model G560/EC
DIAMOND SERIES

+61 (2) 6608 2736 |info@airius.com.au |www.airius.com.au
DIS-G560/EC-230V
2
Product Information & Installation Guide
DIAMOND SERIES - Model G560/EC
IP54 Rated
INGRESS PROTECTION
MOTOR
Single Phase
Electrically commutated, variable speed 92% efficient motor
German EBM Papst EC motor
230 Volt @ 50/60 Hz
OPERATING TEMPERATURES
Min start temp (approx.) = - 10° C
Min running temp = - 25° C
Shut off = 135° C
Reset = 125° C
HOUSING
Hi-Grade Aircraft Alloy - Inc. internal fixed blade stator
5VA flame resistance rating
1.8m steel safety leash cable (fastened to housing)
NOISE LEVELS
Sound Power Level = 78 dB(A)
Sound Pressure Level @ 3 mts = 52 dB(A)
Sound Pressure Level @ 6 mts = 47 dB(A)
Note: A typical free field environment over a reflecting plane.
All acoustic testing conducted at 230 Volt, 50Hz and undertaken at the
EBM- Papst Acoustic Laboratories in Connecticut USA during August 2014
Please contact Airius for full Noise Testing Report
WARRANTY
5 years full manufacturers replacement from date of despatch.
Subsequent 5 year 'half new price' rebuild cover
ACCESSORIES & OPTIONS
Multiple speed control options available:
- Full 0-100% potentiometer speed control option
- Fully programmable Airius touch screen controller
- Airius PearLink WiFi Control
Fully BMS controllable
Bacnet Protocol option for individual fan control
For horizontal installations it is imperative that there is a chain
attached to the eyebolt supplied on the nose of the fan.
COVERAGE COOLING HEATING
Ceiling Height = 8m - 18m = 10m - 20m
Floor area = Up to 250m² = Up to 300m²
All data is indicative only and can change subject to application. For
more accurate design please contact Airius Oceania
COLOUR
Off-White, Black or Grey available
MODEL G560/EC DIMENSIONS AND PROPERTIES
Free hanging units can be angled up to 90º off vertical
Vertical attachment point provided near discharge.
546mm
723mm UNIT SIZE
Weight:
Diameter:
*Motor data provided by motor manufacturer and is subject to change at anytime
¹Velocity profile tested in situ
STANDARD
27.2 kgs
723 mm
Total Height: 546 mm
MOTOR 230V @ 50 Hz
RPM*:
Watts*:
L/S*:
m3/hr:
Centre Line Velocity¹:
400
1000
2454
8835
3.0 m/s @ 10 m
AMPS*: 1.80
Thrust*: 21.28 Newtons

3
DIS-G560/EC-230V
Product Information & Installation Guide
DIAMOND SERIES - Model G560/EC
PREPARATION
Install electrical circuit(s) and outlet(s) in accordance with national
and local electric codes.
Outlets should generally be mounted vertically unless a “twist/
locking” type is being used.
Wall switch may be installed in circuit to disable power and prevent
electrical hazards when servicing.
Confirm electrical continuity of Airius unit on the ground before
permanently mounting in the ceiling.
OPERATION
Designed to operate 24 hours-a-day, 7 days-a-week to maintain air
circulation/thermal equalization/humidity equalization.
Use optional speed control to fine tune RPM if needed.
MAINTENANCE
Frequency of cleaning will vary by application and environment.
You may clean the plastic housing with a damp warm cloth, using
mild household detergents.
Do not use petroleum products, thinners or solvents to clean any
part of the Airius unit.
If the Airius unit fails, contact manufacturer.
MATERIALS & PROPERTIES
Constructed from recyclable materials.
The outer shell, stator and fan blades are fire rated 5VA materials.
Power cord is a 1.8m, 3 wire, 1.02 mm diameter 300VAC rated
electrical cord - CE/EU compliance rated as HO5VV (PLUG NOT
SUPPLIED).
Electrically commutated, variable speed 92% efficient motor.
Motor is thermally protected. Shutoff is at 135°C & reset is at
125°C.
No lubrication required. Bearings are sealed.
UNIT PLACEMENT
INSTALLATION
Do not hard connect fans in excess of 10 kgs unless agreed with
Airius prior to Installation. When attaching it is preferred if some
chain or cable is used between fan and the support. However it is
not imperative.
For Cooling the Airius fan should be located to suit client’s require-
ments. Suggested locations are from just under the ceiling or closer
to the floor to ensure suitable air-cooling flow.
For Heating or Conditioned Spaces the Airius fan should be
securely installed as close as possible to the ceiling.
For combination applications fans can be installed close to ceiling
or lowered slightly. Contact Airius for design details and assistance.
The Airius unit performs best when air column from the nozzle is
unimpeded to the floor.
The Airius unit should not be mounted directly in front of heat
ducts, vents or any other high heat source.
Use professionally installed hardware, capable of supporting a
minimum of five times the weight of the fan unit.
Hardware to hang the unit includes but is not restricted to: Hooks,
chains, cables, carabiners, bridle rings, beam clamps and bolts.
Density of the placement is directly related to the effectiveness,
performance and savings.
Mount out of reach from people and animals.
Floor plans, mezzanines, office locations, machinery, people
placement, plumbing, lighting, duct work, electrical systems, natural
light/air systems, cranes, doors, windows, ventilation and fire
suppression systems are all factors in properly locating the Airius
system within the ceiling.

+61 (2) 6608 2736 |info@airius.com.au |www.airius.com.au
4
DIS-G560/EC-230V
Product Information & Installation Guide
DIAMOND SERIES - Model G560/EC
Mounting Point
Unistrut or Ceiling Beam
PLUG NOT SUPPLIED
CHAIN HUNG (STRAIGHT)
Receptacle Rated
240 VAC
240 v Plug
(single phase)
300 VAC Rated Cord
Furnished 2m
Unit Control Data Cable
To Controller OR mounted WiFi Module
Cable Tie
Cord Secured
To Control Module
Chains should be rated @ 150 Kgs each
(Not supplied).
Chains can be attached using caribiners,
bolts, Chemsets or Dyna Bolts.
Airius Air Circulation
& Destratification Fan
Intake
Exhaust
Factory fitted eye bolt
Intake
Exhaust
Units can be angled
up to 90° off vercal
Unistrut or Ceiling Beam
PLUG NOT SUPPLIED
CHAIN HUNG (ANGLED)
Receptacle Rated
240 VAC
240 v Plug
(single phase)
300 VAC Rated Cord
Furnished 2m
Cable Tie
Cord Secured
To Control Module
Airius Air Circulation
& Destratification Fan
Unit Control Data Cable
To Controller OR mounted WiFi Module
Factory fitted eye bolt
Chains should be rated @ 150 Kgs each
(Not supplied).
Chains can be attached using caribiners,
bolts, Chemsets or Dyna Bolts.
Mounting Point

+61 (2) 6608 2736 |info@airius.com.au |www.airius.com.au
5
DIS-G560/EC-230V
Product Information & Installation Guide
DIAMOND SERIES - Model G560/EC
CONTROL WIRING CONNECTIONS
FULL SPEED WIRING
Connect:
0-10v PWM+10v
SPEED CONTROLLABLE WIRING
Connect:
0-10v PWM+10vGND
Speed Control
(Potentiometer)
GND
GND
+10v
0-10v PWM
0-10v PWM
NOTE: 0-10 volt analogue signal supplied by fan motor. 3 wire low
voltage cable or Cat 5 or Cat 6 cable to be used to either an Airius
Potentiometer or a BMS controller (by others).

+61 (2) 6608 2736 |info@airius.com.au |www.airius.com.au
6
DIS-G560/EC-230V
Product Information & Installation Guide
DIAMOND SERIES - Model G560/EC
PEARLINK
Reduce installation cost & control your
Airius fan system over 2.4Ghz WiFi
DISTRIBUTED COMFORT
The PearLink control system offers total fan control from a
desktop or mobile device. It integrates with existing Wi-Fi to
provide wireless connectivity for monitoring air
temperatures and stratification levels for cooling and heating
applications and to provide individual or grouped fan control.
This factory installed option will replace all control wiring and
manual wall controls. Each installation can, at a small cost,
include a floor sensor to be installed near your thermostat to
monitor room temperature and stratification levels.
WHERE WE HELP
»Reduce installation cost by eliminating control wiring
»Control fans individually or in groups over 2.4Ghz WiFi
»Provide fan control from anywhere in the world on your
portable device or laptop
FEATURES
»Interface is web-based (Chrome/Firefox), iOS, or Android
»Monitor temperature and humidity at fan and floor level
»Utilise temperature information to provide cooling air flow
»Monitor Delta-T (stratification level)
»Monitor fans via the integrated tachometer
»Alerts for run time and/or stratification
»Upgrade firmware via Over The Air (OTA) encrypted
firmware updates

+61 (2) 6608 2736 |info@airius.com.au |www.airius.com.au
DIS-G560/EC-230V
7
Product Information & Installation Guide
DIAMOND SERIES - Model G560/EC
AIRIUS FAN SYSTEM
AIRIUS CONTROLS SERVER
PHONE OR TABLET
Housing: PC/ABS, Off white (cool gray 2c)
Mounng: Factory installed at time of ordering.
Power Consumpon
Idle: 16mA
TX/RX: 200mA
Wi-Fi Characteriscs
802.11b/g/n 2.4 GHz
TX Power 18 dBm @ 1DSSS
RX Sensitivity -96 dBm @ 1 DSSS
Range 100 meters
Sensors & Accuracy
Temperature Sensor +/- 0.5˚C
Humidity Sensor +/- 1% RH
Tachometer +/- 3%
Interface
Web-based (Chrome/Firefox), iOS, or Android (Mobile apps
available in App Store and Google Play Store)
Requirements
2.4 GHz Wi-Fi network
Phone or tablet with iOS 8 or later, or Android 4 or later required
for setup
Browser for accessing the web dashboard to control devices (PC or
MAC)
A free PearLink Account
Operang Condions
Temperature 0 to 48.8˚C
Humidity Up to 90% RH
Altitude Up to 3,300 mts
Ordering
The PearLink control is a factory installed option. Please refer to the
individual model data sheets for configuring your fan.
Warranty
1 years parts and workmanship.

+61 (2) 6608 2736 |info@airius.com.au |www.airius.com.au
DIS-G560/EC-230V
8
Product Information & Installation Guide
DIAMOND SERIES - Model G560/EC
PEARLINK
Quick Setup Guide
ACCOUNT CREATION
Once you have purchased your Airius Wi-Fi fans, simply download the free 'Pearlink Wireless Fan Control' app from the app
store or visit https://controls.airiusfans.com/ dashboard/login and create an account using your email address to log in.
This is your command-and-control portal for the Airius fans at your facility. You can use the web based dashboard or the the
Airius PearLink mobile app, available for both iOS and Android, to operate fans to fully control the air movement in a room.
What you will need before moving on:
> Your Wi-Fi network name and associated password
> Android, iOS device, laptop or desktop computer (for provisioning)
> Height of each fan A.F.F. (above finished floor)
To begin, please download and install the Airius 'PearLink Wireless Fan Control' app, which can be found on the Google Play
or Apple Stores, or visit:
>
https://controls.airiusfans.com/dashboard/login.
email: [email protected]

+61 (2) 6608 2736 |info@airius.com.au |www.airius.com.au
DIS-G560/EC-230V
9
Product Information & Installation Guide
DIAMOND SERIES - Model G560/EC
> >
> >
PROVISIONING DEVICES
The Airius fan system should be installed, powered and within Wi-Fi range along with the Android/iOS device used to
provision the fans. The floor sensor should be located within the same space, connected to power using the small transformer
supplied and installed 1.5-1.8 mts A.F.F. Preferably next to your existing thermostat.
Open the Airius App and enter your email address and password to log in. You are now ready toprovision your devices.
Note: the screen shots are from an Android device and might vary slightly for iOS devices.
Press the “Add new device” button: Grant Wi-Fi Permission Enter your Wi-Fi credentials
Press the “Ready” button: Choose your device. Provision all
floor sensors before any fans.
App will provision device

+61 (2) 6608 2736 |info@airius.com.au |www.airius.com.au
DIS-G560/EC-230V
10
Product Information & Installation Guide
DIAMOND SERIES - Model G560/EC
>
>
>
>
Name the device Continue Enter the associated invoice number
Enter the ceiling height where the
fan is installed
Review the information and select
the correct fan model from the drop
down menu
Select, “Add new device and apply
most recent profile” > Follow the
same steps for each device
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Airius Ventilateur

Airius
Airius AIR PEAR 25/EC Manuel utilisateur

Airius
Airius Q Series Manuel du propriétaire

Airius
Airius SAPPHIRE Series Manuel utilisateur

Airius
Airius R20/EC Eyeball Manuel utilisateur

Airius
Airius ONYX Series Manuel utilisateur

Airius
Airius RETAIL R20/EC Eyeball Manuel utilisateur

Airius
Airius 45/EC Manuel utilisateur

Airius
Airius RETAIL R20/EC Manuel utilisateur

Airius
Airius R20/EC Duckbill Manuel utilisateur

Airius
Airius 50/EC Manuel utilisateur