Agilent Technologies Keysight N9310A Manuel utilisateur

Agilent N9310A
RF Signal Generator
Quick Start Guide

Notices
© Agilent Technologies, Inc. 2006
No part of this manual may be reproduced
in any form or by any means (including
electronic storage and retrieval or transla-
tion into a foreign language) without prior
agreement and written consent from Agi-
lent Technologies, Inc. as governed by
United States and international copyright
laws.
Edition
First Edition, June 2006
Printed in China
Agilent Technologies, Inc.
Qianfeng Hi-Tech Industrial Park
Chengdu Hi-Tech Industrial Development
Zone(West District)
Chengdu, 611731, P.R.C
Warranty
The material contained in this docu-
ment is provided “as is,” and is sub-
ject to being changed, without notice,
in future editions. Further, to the max-
imum extent permitted by applicable
law, Agilent disclaims all warranties,
either express or implied, with regard
to this manual and any information
contained herein, including but not
limited to the implied warranties of
merchantability and fitness for a par-
ticular purpose. Agilent shall not be
liable for errors or for incidental or
consequential damages in connection
with the furnishing, use, or perfor-
mance of this document or of any
information contained herein. Should
Agilent and the user have a separate
written agreement with warranty
terms covering the material in this
document that conflict with these
terms, the warranty terms in the sep-
arate agreement shall control.
Technology Licenses
The hardware and/or software described in
this document are furnished under a
license and may be used or copied only in
accordance with the terms of such license.
Restricted Rights Legend
U.S. Government Restricted Rights. Soft-
ware and technical data rights granted to
the federal government include only those
rights customarily provided to end user cus-
tomers. Agilent provides this customary
commercial license in Software and techni-
cal data pursuant to FAR 12.211 (Technical
Data) and 12.212 (Computer Software) and,
for the Department of Defense, DFARS
252.227-7015 (Technical Data - Commercial
Items) and DFARS 227.7202-3 (Rights in
Commercial Computer Software or Com-
puter Software Documentation).
Safety Notices
CAUTION
A CAUTION notice denotes a haz-
ard. It calls attention to an operat-
ing procedure, practice, or the like
that, if not correctly performed or
adhered to, could result in damage
to the product or loss of important
data. Do not proceed beyond a
CAUTION notice until the indi-
cated conditions are fully under-
stood and met.
WARNING
A WARNING notice denotes a
hazard. It calls attention to an
operating procedure, practice, or
the like that, if not correctly per-
formed or adhered to, could result
in personal injury or death. Do not
proceed beyond a WARNING
notice until the indicated condi-
tions are fully understood and
met.
Software Revision
This guide is valid for V1.0 revisions of the
Agilent N9310A RF Signal Generator
software. Due to our continious effert to
improve our product, please go to our web
site to download the latest version of the
Quick Start Guide or User’s Guide.

1
Quick Start Guide
This
Quick Start Guide
helps you in preparing the signal
generator for use. With this guide, you will become familiar
with its basic operation and programming information. For
more information, please refer to
User’s Guide
from:
www.agilent.com/find/n9310a
N9310 Overview 4
Preparation for Use 7
Generating a Continuous Wave Signal 9
Generating a Step Sweep Signal 11
Generating a Modulated Signal 13
Some Help Hints 15
Remote Control 16
Contact Agilent Technologies 22
Factory Default Settings 23

2Quick Start Guide
N9310A RF Signal Generator
Check the Shipment
After receiving the shipment, you should first check the
shipment and your order list refer to the procedures below.
✔Inspect the shipping container for damage.
Signs of damage may include a dented or torn shipping
container or cushioning material that indicates signs of
unusual stress or compacting.
✔Carefully remove the contents from the shipping container
and verify that your order is complete. Each signal
generator includes the following items as standard:
✔Verify if the ordered options are included in the shipment
by checking the serial number on the rear panel of the
signal generator:
Any question about your shipment, please contact Agilent
Technologies Customer Contact Center for consulting and
service.
Item Quantity Part Number
N9310A signal generator 1 N9310A
USB cable 1 8121-1482
three-pin power cord 1 Specific to location
Quick Start Guide 1 N9310-90003
User’s Guide 1 N9310-90001
Help kit CD-ROM 1 N9310-84500
Calibration certificate 1 N/A
Option Name Part number
001 I/Q modulator N9310A-001
1CM Rackmount flange kit N9310A-1CM
1TC Hard transit case N9310A-1TC

N9310A RF Signal generator
Quick Start Guide 3
Safety Notice
Please read the following warnings and cautions carefully
before you power on the signal generator to ensure your
personal and instrumental safety.
WARNING Always use a well-grounded, three-pin AC plug and power cord to
connect to a power source. Personal injury may occur if there is any
interruption of the AC power cord of the signal generator. Intentional
interruption is prohibited.
WARNING Personal injury may result if the signal generator covers are removed.
There are no operator serviceable parts inside. To avoid electrical
shock, refer servicing to qualified personnel.
WARNING Electrical shock may result if the signal generator is connected from
the power supply while cleaning. Do not attempt to clean
internally.
CAUTION To install the signal generators in other racks, note that they may
promote shock hazards, overheating, dusting contamination, and
inferior system performance. Consult your Agilent customer engineer
about installation, warranty, and support details.
CAUTION Damage to the signal generator may result when the total power
dissipated in the cabinet is greater than 800 watts. When this
condition exists, forced convection must be applied.
CAUTION The RF OUT connector is for signal output only. Avoid manually adding
any external signal into the signal generator via this connector. This
connector endures maximum +36 dBm RF power or 30 V DC input
(1 minute lasting). Or it may result in instrument damages.

4Quick Start Guide
N9310A RF Signal Generator
N9310 Overview
An Agilent N9310A RF Signal Generator finds general
purpose test application between 9 kHz to 3 GHz. It is
capable to generate variables of signals as shown below,
which could be applied in the field of manufacture, service
and repair, development and education:
• Continuous wave (CW) signal
•Lowfrequency(LF)signal
• RF/LF/Amplitude step sweep
• Amplitude modulation (AM) signal
• Frequency modulation (FM) signal
•Phasemodulation(FM) signal
•Pulsemodulationsignal
The signal generator comprises an optional broadband I/Q
modulator (option 001). With this option, N9310A is capable
of generating complicated digital signal widely used in
modern digital communication system in conjunction with an
external I/Q signal generator.
The N9310A RF Signal Generator has USB connectors for
yourremote control and fast file transferring.

N9310A RF Signal generator
Quick Start Guide 5
The Front Panel at a Glance
FUNCTIONS
LF OU T RF OU T 50
Rem ote
Standby
On
N9310A RF Signal Gen erator 9 kHz - 3. 0 GHz
Frequency
Amplitude
Enter
7
4
1
8
9
56
23
0
MOD
On/Off
On/Off
RF
I/Q
FM
Preset
AM
FMPulse
Utility
Sweep
Trigger
LocalFile
LF Out
1
.
8
9
10
11
12
13
18
17
16
15
14
7
56
4
3
2
REV ERSE PWR
4W MA X 30VD C
1Screen 10 RF On/Off hardkey
2Softkeys 11 RF OUT connector
3Enter key 12 LF OUT connector
4Amplitude hardkey 13 Numeric keypad
5Frequency hardkey 14 Standby switch
6Function hardkeys 15 Switch On LED
7Mod On/Off hardkey 16 Standby LED
8Knob 17 Remote LED
9Arrow hardkeys 18 USB Device connector

6Quick Start Guide
N9310A RF Signal Generator
The Rear Panel at a Glance
The signal generator rear panel provides input, output, and
remote interface connections. Refer to “Rear Panel Overview”
on
User’s Guide
for more information.
VGA OUTPUT
DEV
TRIG IN
HOST
MOD IN
PULSE M OD I N
REF IN
REF OUT
I IN 1V RMS
MAX
Q IN
LINE:
100-240V
50-60Hz
100W MAX
Made in China
HIPOT PASS
N9310A N9310A-CFG002
SER:CN*********
1
3
4
6
7
8
9
10
11 12
2
5
1 AC power switch 7 Pulse input connector
2 AC power connector 8 Modulation source input connector
3 USB host connector 9 Q input connector
4 Trigger input connector 10 I input connector
5 Reference output connector 11 VGA connector
6 Reference input connector 12 USB device connectors

N9310A RF Signal generator
Quick Start Guide 7
Preparation for Use
1Connect the power cord. Insert the plug into a power socket
provided with a protective earth. Set the tilt adjustor for
your preference.
2Connect an RF cable to the output connector of the signal
generator and then connect the cable to your DUT (device
under test) or other instrument.
D
U
T

8Quick Start Guide
N9310A RF Signal Generator
Turn On the Signal Generator
Follow this procedure to power on the signal generator:
1Press the power switch on the rear panel. The orange
LED will light and the signal generator is in standby mode.
2Press the standby switch on the front panel. The green
LED will light.
Self- initialization takes about 30 seconds; the signal
generator then defaults to the menu mode with the
maximum frequency of 3 GHz and minimum amplitude of
–127 dBm, then the signal generator is ready for your
current use. After power on, let the signal generator warm
up for 45 minutes for stabilization.
NOTE The front panel switch is a standby switch only; it is not a power
switch. To disconnect the signal generator from the line power, shut
off the power switch on the rear panel.
Autres manuels pour Keysight N9310A
2
Table des matières
Autres manuels Agilent Technologies Processeur de signal

Agilent Technologies
Agilent Technologies E8257D Manuel d'installation et d'exploitation

Agilent Technologies
Agilent Technologies Keysight N9310A Manuel utilisateur

Agilent Technologies
Agilent Technologies N9310A-001 Manuel utilisateur

Agilent Technologies
Agilent Technologies HP 83711A Manuel d'utilisation et d'entretien