Afag Electric Slide Series Manuel d'exploitation

Electric Slide
ES8 I ES12
Installation declaration
Module Data
Installation manual
Maintenance manual
Translation of the original operating manual
© Copyright by Afag Automation AG

2 ES8-ES12-BA vers. 1.3 en. 20190311
This operating manual is valid for:
Type Order number
ES8-15 50433800
ES8-40
50433801
ES12-20
ES12-60
ES12-100
50433802
50433803
50433804
Installation and commissioning only by qualified personnel in accordance with the instal-
lation manual.
Version of this
documentation:
ES8-ES12-BA vers. 1.3 en. 20190311
Explanation of symbols and signs:
DANGER
Designates a directly threatening danger. If the information is
not observed, death or most severe injury (invalidity) will be the
consequence!
WARNING
Designates a possible dangerous situation.
If the information is not observed, death or most severe injury
(invalidity) will be the consequence.
CAUTION
Designates a potentially dangerous situation.
If the information is not observed, property damage or light to
moderate injury will be the consequence.
NOTE
Draws attention to general notes, useful tips for the operator and
working recommendations, but which have no influence on the
health and safety of the personnel.
The current serial number is attached here
on delivery of the machine

ES8-ES12-BA vers. 1.3 en. 20190311 3
Table of Contents
1 Declaration of Incorporation for Partly Completed Machinery ................. 5
1.1 Machinery Directive: EC Directive 2006/42/EC .............................................. 5
2 Module Data .................................................................................................. 6
2.1 Safety instructions .......................................................................................... 6
2.2 Transport, handling, storage ........................................................................... 6
2.3 Description of the electric slide ....................................................................... 7
2.4 User instructions ............................................................................................. 7
2.5 Observe the notes in the operating manual! ................................................... 8
2.6 Protection against dangerous movements ..................................................... 9
2.7 Installation, connection ................................................................................... 9
2.8 Mounting Instructions ................................................................................... 11
2.9 Centring Sleeves .......................................................................................... 12
2.10 Tightening Torques for Bolts ........................................................................ 13
2.11 Operating Conditions .................................................................................... 13
2.12 Installation of the ES Electric Slides in a System ......................................... 14
2.13 Electric Slide ES8 ......................................................................................... 15
2.14 Preferred combinations for ES8 ................................................................... 16
2.15 Preferred combinations for ES12 ................................................................. 17
2.16 Programming the ES Electric Slides ............................................................. 18
3 Installation manual ..................................................................................... 19
3.1 Manufacturer's address: ............................................................................... 19
3.2 Scope of delivery .......................................................................................... 20
3.3 Intended use ................................................................................................. 20
3.4 Warranty and liability .................................................................................... 21
3.5 Safety instructions ........................................................................................ 21
3.6 Dimensional drawing ES8 ............................................................................ 22
3.7 Technical data ES8 ...................................................................................... 23
3.8 Module loads ES8 ........................................................................................ 24
3.9 Dimensional drawing ES12 .......................................................................... 25
3.10 Technical data ES12 .................................................................................... 26
3.11 Module loads ES12 ...................................................................................... 27
3.12 Safety fence at the installation site ............................................................... 28

4 ES8-ES12-BA vers. 1.3 en. 20190311
3.13 Commissioning, operation, training .............................................................. 28
3.14 Preparations prior to commissioning ............................................................ 29
3.15 Commissioning ............................................................................................. 30
3.16 Setup, Retrofitting ......................................................................................... 31
3.17 Normal operation .......................................................................................... 32
3.18 Setting speeds at the electric axes ............................................................... 33
4 Maintenance ................................................................................................ 34
4.1 After commissioning ..................................................................................... 34
4.2 Every 3 months ............................................................................................ 34
4.3 Repairs ......................................................................................................... 35
5 Accessories ................................................................................................. 36
5.1 Servo controller Overview ............................................................................ 36
5.2 Servo controller Technical Data ................................................................... 37
5.3 Overview, controller, cable, plug .................................................................. 40
5.4 Dimensional drawings for cable types .......................................................... 42
6 Disposal ....................................................................................................... 44

ES8-ES12-BA vers. 1.3 en. 20190311 5
1 Declaration of Incorporation for Partly Completed Machinery
1.1 Machinery Directive: EC Directive 2006/42/EC
Standard: EN ISO 12100:2010 (German version)
The manufacturer:
Afag Automation AG, Fiechtenstrasse 32, CH-4950 Huttwil, Switzerland
hereby declares that the following products:
ES8-15
ES8-40
ES12-20
ES12-60
ES12-100
comply with the applicable EC Directives:
EC Low-Voltage Directive: 2014/35/EU
EMC Directive 2014/30/EU
Applied harmonised standards: EN 349; EN 60204-1:2006
- Safety of machinery - General principles for design - Risk assessment and
risk reduction
- In response to a duly substantiated request, these special technical documents will
be submitted to the competent national authorities as printed documents or in elec-
tronic form (pdf).
Directive: Applied and satisfied fundamental requirements:
1.1; 1.1.1; 1.1.2; 1.1.3, 1.1.5, 1.3.2, 1.3.4 and 1.5.1
The person or company installing this partly completed machinery or combining it with
other machinery must carry out a risk assessment for the resulting machinery that satis-
fies the requirements of the EC Directive: 2006/42/EC.
Standard: EN ISO 12100:2010 (German version)
Authorised representative:
Responsibility for the compilation of the technically relevant documents lies with:
Niklaus Röthlisberger, Product Manager, Afag Automation AG, CH-4950 Huttwil
Place/date: Huttwil, 11.03.2019
Siegfried Egli
Managing Director
Afag Automation AG
Niklaus Röthlisberger
Product Manager
Afag Automation AG

6 ES8-ES12-BA vers. 1.3 en. 20190311
2 Module Data
2.1 Safety instructions
DANGER
The strong magnetic fields (even when the module is switched
off) can interfere with electronic devices, e.g. heart pacemakers,
or impair their function.
Persons with a heart pacemakers must keep a safety distance
of at least 50 cm.
No modifications may be made to the ES Electric Slide that are not described in this in-
stallation manual or have been approved in writing by Afag Automation AG. Afag Auto-
mation AG will assume no liability for any unauthorised modifications or for improper
erection, installation, operation, maintenance or repair.
2.2 Transport, handling, storage
The following values must be observed during transport and storage:
Storage temperature: 0-50°C
Humidity: < 90%, non-condensing
CAUTION
Take care when packing and unpacking the ES Electric Slides!
Careless handling of the electric slide can result in fingers be-
ing crushed as the electric slide can move back and forth when
loose!
The slide is transported in the transport packaging from Afag Automation AG.
If the packaging from Afag Automation AG is not used, the electric slide must be packed
so that it is protected against impact and dust.
The electric slides must be stored dry in the transport packaging.
The electric slides weigh from 0.1 to 0.4 kg (depending on stroke length).
NOTE
Please note!
A safety information sheet is included with each module. This infor-
mation sheet must be read by every person involved with the mod-
ule.

ES8-ES12-BA vers. 1.3 en. 20190311 7
2.3 Description of the electric slide
The ES Electric Slides are used in automation systems and are intended exclusively for
the movement of workpieces.
The ES Electric Slides are intended exclusively for operation with original LinMot compo-
nents (controllers, cables, etc.). Use for any other purpose does not constitute an intend-
ed use.
The intended use also includes compliance with the prescribed installation and removal
instructions, the service and maintenance conditions and observance of the specifica-
tions in the data sheets.
Pay attention to magnetic fields!
DANGER
The strong magnetic fields (even when the module is switched
off) can interfere with electronic devices, e.g. heart pacemakers,
or impair their function.
Persons with a heart pacemaker must keep a safety distance of
at least 50 cm.
2.4 User instructions
The ES Electric Slides are built to the state-of-the-art and the generally accepted safety
regulations and may only be used
For the intended purpose
In an operationally safe condition

8 ES8-ES12-BA vers. 1.3 en. 20190311
Description of the electric slide
ES Electric Slides are available in the following versions:
Type
Stroke
Order number
ES8-15 15 mm 50433800
ES8-40 40 mm 50433801
ES12-20 20 mm 50433802
ES12-60 60 mm 50433803
ES12-100 100 mm 50433804
Installation and commissioning only by qualified personnel in accordance with the instal-
lation manual.
2.5 Observe the notes in the operating manual!
A precondition for the safe handling and problem-free operation of the ES Electric Slides
is the knowledge of the fundamental safety regulations.
All persons involved in the installation, commissioning, maintenance and operation of the
ES machines must have read and understood the complete operating manual, in particu-
lar the chapter "Safety instructions".
Furthermore, the rules and regulations on accident prevention applicable at the place of
installation/operation must also be observed. Improper use may result in dangers to the
life and limb of the operator or third parties and in impairments to the machine or other
assets.
In the event of faults that could impair safety, the machine must be switched off immedi-
ately and secured to prevent restarting. The fault must then be remedied.
All work on the machines must be carried out with the machines depressurised and dis-
connected from the electrical power supply.
For the operation of the machines, the user must provide safety hoods, safety doors or
other safety precautions conforming to the normal safety guidelines and safety standards
which prevent people from entering or remaining in the working area of the machines
during operation. The machines may only be put into operation when the guards are se-
curely closed.

ES8-ES12-BA vers. 1.3 en. 20190311 9
2.6 Protection against dangerous movements
Dangerous movements can occur if drives are actuated incorrectly. The drive compo-
nents are monitored so that a malfunction can be effectively ruled out. For reasons of
personal safety, the risk of injury and the risk of material damage, however, this must not
be relied on completely. Faulty drive movements must be expected until installed moni-
toring devices become active.
2.7 Installation, connection
WARNING
The ES Electric Slides are set in motion by the electric control
system. If the Electric Slides cannot move freely, there is a risk
of injury and crushing in conjunction with attachments.
If attachments on the Electric Slides can pose a hazard in con-
junction with the moving slides or the superstructures, a corre-
spondingly safe operation must be ensured.
WARNING
Due to the decentralised control unit, the operator of the Elec-
tric Slide is not necessarily alongside the product and can
therefore endanger other persons in other areas.
For work at the Electric Slides, turn off the control unit of the
module and secure it against unintentional restarts. Signals
from the control unit can lead to unintentional movements of
the module, which can cause injuries.

10 ES8-ES12-BA vers. 1.3 en. 20190311
CAUTION
The ES Electric Slide is a partially completed machine.
For safe operation, the ES Electric Slide must be integrated into
the safety concept of the plant in which it is installed.
Measures must be taken to ensure that the operating personnel
cannot enter the working area of the ES Electric Slides during
operation.
Depending on the version and the installation, there is an addi-
tional safety risk, e.g. of pinching fingers!
The ES Electric Slide may only be used for its intended pur-
pose.
Measures must be taken to ensure that the operator cannot en-
ter the working area of the ES Electric Slide during normal op-
eration. This can be achieved by suitable protective measures
such as enclosures, light barriers or de-energisation of the
drive.
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels Afag Contrôleurs

Afag
Afag SIGA B.7/65.1 V6 Manuel utilisateur

Afag
Afag IRG 1-S Manuel utilisateur

Afag
Afag IRG 1-MS Schéma de câblage

Afag
Afag SE-Power FS Manuel utilisateur

Afag
Afag PSG 1 Manuel utilisateur

Afag
Afag SE-24 Manuel utilisateur

Afag
Afag SE-24 Manuel utilisateur

Afag
Afag IRG 1-S Manuel utilisateur

Afag
Afag KLF 5 Manuel utilisateur