Aero Storm 52 Mode d’emploi

Storm 52
ATTENTION ELECTRICIANS:
ANY PROBLEMS FOUND DURING INSTALLATION OF THE FAN PLEASE CONTACT THE NATIONAL
WARRANTY NUMBER PRIOR TO LEAVING SITE.
DO NOT REMOVE THE FAN FROM THE CEILING
UNLESS INSTRUCTED TO DO SO.
National Warranty Number | 1300 116 305 Monday to Friday 9am to 5pm AEST
gNOTE: THIS FAN MUST BE INSTALLED BY A LICENSED AND QUALIFIED
ELECTRICIAN IN ACCORDANCE WITH LOCAL AUTHORITY REGULATIONS
Australian Edition Version 2.1 April 2020
Installation & User Manual
PLEASE NOTE: THE REMOTE CONTROL COMES PRE-PROGRAMMED TO THE FAN
REPROGRAMMING IS ONLY REQURED WHEN REPLACING THE REMOTE CONTROL

NOTE: THIS FAN MUST BE INSTALLED BY A LICENSED AND QUALIFIED
ELECTRICIAN IN ACCORDANCE WITH LOCAL AUTHORITY REGULATIONS
1
IMPORTANT INFORMATION - PLEASE READ BEFORE ATTEMPTING INSTALLATION
1. Please read these instructions carefully, be mindful of all warnings and safety information shown throughout this
manual. Should you have any questions, please contact 1300 116 305.
2. Please review the accompanying assembly diagrams before attempting installation.
3. This fan MUST be installed by a licensed & qualied electrician according to local authority regulations. Therefore,
to protect our repair personnel, on-site warranty claims will not be accepted if products have been installed by
unlicensed persons.
4. A copy of the purchasing receipt and proof of installation by a licensed and qualied electrician according to local
authority regulations is required for all warranty claims.
5. Where special access equipment is required in accordance with local authority regulations all associated costs are
the responsibility of the owner.
6. We reserve the right to charge a $175 service fee for all call outs where the fan is found not to be defective and
/ or where access is not provided.
7. An isolation switch providing full disconnection of both fan and light must be tted in accordance with the wiring
rules (AS/NZS 60335.1 C1.7.12.2).
8. Your warranty will be void if a solid state dimmer or any other brand of wall controller is used.
9. To avoid possible electric shock during installation, be sure electricity is turned off at the main power box before
commencing work. Disconnect power by removing fuse or turning off circuit breaker before installing the fan.
Ensure all spliced connections are adequately insulated.
10. Warning! Do not allow the rotating fan blades to come into contact with any object, this can cause serious injury
or death.
11. Damage caused by; incorrect installation, Force-majeure, lightning, electrical surges & spikes, exposure to water,
pests or moisture is not covered under warranty.
12. In accordance with AS/NZS60355-1 & ASNZS60355-2-80: “This appliance is not intended for use by persons
(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the appliance by a person responsible
for their safety. Children should be supervised to ensure that they do not play with the appliance.”
13. Children should be supervised to ensure that they do not play with the appliance.
14. Children shall not play with the appliance.
15. Cleaning and user maintenance shall not be made by children.
16. Blades must be replaced only as a complete set. Blades are supplied only as a pre-balanced set and the
replacement of individual blades may void the warranty by causing mechanical damage to the motor, excessive
noise or premature wear.
Please Note: Nothing in this manual is intended to instruct or assist untrained or
unqualied persons to install this product. Additionally, it is the responsibility of the
installer and user to apply common sense and care at all times.
Please note: Minor design changes may result in slight variations between the product illustrations and the fan contained within the packaging.

National Warranty Hotline|1300 116 305 Monday to Friday 9am to 5pm AEST 2
LOCATION AND INSTALLATION REQUIREMENTS
Provide adequate clearance from the oor. The lowest point on the
fan blades must be at least 2.1m (7 feet) from oor level in Australia
and at least 2.3m from oor level in the European Union and afliated
countries.
Make sure that the chosen location of the fan will not allow the rotating
fan blades to come into contact with any objects.
Ensure ceiling joists are sound and of adequate size and strength to
support a 25Kg (55lb) load.
To reduce the risk of re, electrical shock or personal injury, ensure
that the fan mounting bracket is supported directly from the building
structure. DO NOT mount to an outlet box.
The mounting bracket must be rmly screwed to a load bearing structure e.g. a concrete ceiling, steel structure or
timber frame. If a timber frame is to be added it must be securely nailed or screwed between two beams.
After the fan is completely installed, check to make sure that all connections are secure to prevent the fan from falling
and/or causing damage or injury.
To reduce the risk of personal injury, do not bend or damage the motor or Fan Assembly when handling or during
installation.
Please ensure special care is taken when assembling the fan. Each screw must be sufciently tightened.
TABLE OF CONTENTS
Fan assembly & parts list - without LED light kit.........................
Fan assembly & parts list - with LED light kit..............................
Installing extension rod (optional accessory)..............................
Installing hanger bracket..........................................................
Installing fan - without LED light..............................................
Installing fan - with LED light....................................................
Fanremotecontrolreprogramming..............................................
Operating the fan from the remote control.................................
Replacing LED Panel if required................................................
Summer and Winter Mode Explained.........................................
General Information.................................................................
General maintenance & cleaning...............................................
Troubleshooting.......................................................................
Ceiling fan warranty information................................................
Not covered by warranty...........................................................
Documents to retain for future warranty claims..........................
Electrician Checklist..................................................................
Page 3
Page 4
Page 5
Page 6
Page 7
Page 9
Page 11
Page 11
Page 12
Page 13
Page 14
Page 14
Page 15
Page 16
Page 17
Page 17
Page 18
minimum
2100mm
Floor Level
Ceiling

NOTE: THIS FAN MUST BE INSTALLED BY A LICENSED AND QUALIFIED
ELECTRICIAN IN ACCORDANCE WITH LOCAL AUTHORITY REGULATIONS
3
FAN ASSEMBLY & PARTS LIST - WITHOUT LIGHT KIT
Unpacking your Fan
Unpack your fan and check the contents. Please check each item prior to installation, should you nd any issues please
contact the Warranty Helpline on 1300 116 305 for assistance. To reduce the chance of marks or possible damage
please only remove the parts when required for installation.
To avoid possible electrical shock, be sure
electricity is turned off at the main fuse box
before assembling and wiring the fan.
WARNING
Hanger Bracket
Bracket Mounting Screw
Hanger Ball Screw
Ceiling Canopy
Receiver
Downrod
Downrod Joint Cover
Fan Motor
Blade
Blade Screw
Bottom Cover
Hanger Ball
Part Quantity Part Quantity
Hanger Bracket 1 Fan Motor 1
Bracket Mounting Screws 2 Blades 5
Hanger Ball 1 Blade Screws 15
Hanger Ball Screws 2 Bottom Cover 1
Ceiling Canopy 1 Receiver 1
Downrod 1 Handset 1
Downrod Joint Cover 1
Handset

National Warranty Hotline|1300 116 305 Monday to Friday 9am to 5pm AEST 4
FAN ASSEMBLY & PARTS LIST - WITH LED LIGHT KIT
Unpacking your Fan
Unpack your fan and check the contents. Please check each item prior to installation, should you nd any issues please
contact the Warranty Helpline on 1300 116 305 for assistance. To reduce the chance of marks or possible damage
please only remove the parts when required for installation.
To avoid possible electrical shock, be sure
electricity is turned off at the main fuse box
before assembling and wiring the fan.
WARNING
Hanger Bracket
Receiver
Bracket Mounting Screw
Hanger Bracket
Ceiling Canopy
Downrod
Downrod Joint Cover
Fan Motor
LED Lamp
Blade
Blade Screw
Lamp Cover
Lamp Panel Cover
Part Quantity Part Quantity
Hanger Bracket 1 Fan Motor 1
Bracket Mounting Screws 2 Blades 5
Hanger Ball 1 Blade Screws 15
Hanger Ball Screws 2 Lamp Cover 1
Ceiling Canopy 1 Receiver 1
Downrod 1 Handset 1
Downrod Joint Cover 1 LED Lamp 1
Lamp Panel Cover 1
Handset
Hanger Ball
Mounting Screw

NOTE: THIS FAN MUST BE INSTALLED BY A LICENSED AND QUALIFIED
ELECTRICIAN IN ACCORDANCE WITH LOCAL AUTHORITY REGULATIONS
5
DANGER! Before commencing installation, turn off electricity supply at the main power
box or disconnect power by removing fuse or turning off circuit breaker. This fan must be
installed by a licensed and qualied electrician in accordance with local authority regulations.
INSTALLING EXTENSION ROD (OPTIONAL ACCESSORY)
In accordance with Australian Standards, the fan blades must be at least 2.1 metres above oor level and the blades
require at least 300mm clearance to the nearest object.
PLEASE NOTE: The with light fan includes a second
connector in the wiring loom for the light kit.

National Warranty Hotline|1300 116 305 Monday to Friday 9am to 5pm AEST 6
INSTALLING EXTENSION ROD (OPTIONAL ACCESSORY) CONTINUED
WITHOUT LIGHT LOOM & FAN
(LOOM A)
WITH LIGHT LOOM & FAN
(LOOM B)
INSTALLING HANGER BRACKET - ENSURE CAN TAKE 10KG LOAD
12
3

NOTE: THIS FAN MUST BE INSTALLED BY A LICENSED AND QUALIFIED
ELECTRICIAN IN ACCORDANCE WITH LOCAL AUTHORITY REGULATIONS
7
DANGER! Before commencing installation, turn off electricity supply at the main power
box or disconnect power by removing fuse or turning off circuit breaker. This fan must be
installed by a licensed and qualied electrician in accordance with local authority regulations.
INSTALLING FAN - WITHOUT LIGHT
In accordance with Australian Standards, the fan blades must be at least 2.1 metres above oor level and the blades
require at least 300mm clearance to the nearest object.
1
3
2
4
5
6
6

National Warranty Hotline|1300 116 305 Monday to Friday 9am to 5pm AEST 8
INSTALLING FAN - WITHOUT LIGHT CONTINUED
7 8
910
11
DANGER! Before commencing installation, turn off electricity supply at the main power
box or disconnect power by removing fuse or turning off circuit breaker. This fan must be
installed by a licensed and qualied electrician in accordance with local authority regulations.

NOTE: THIS FAN MUST BE INSTALLED BY A LICENSED AND QUALIFIED
ELECTRICIAN IN ACCORDANCE WITH LOCAL AUTHORITY REGULATIONS
9
DANGER! Before commencing installation, turn off electricity supply at the main power
box or disconnect power by removing fuse or turning off circuit breaker. This fan must be
installed by a licensed and qualied electrician in accordance with local authority regulations.
INSTALLING FAN - WITH LIGHT
In accordance with Australian Standards, the fan blades must be at least 2.1 metres above oor level and the blades
require at least 300mm clearance to the nearest object.
1 2
3 4
56
Table des matières
Autres manuels Aero Ventilateur