AerAtron AE2+ Series Instructions d'installation et d'utilisation

USER MANUAL & INSTALLATION GUIDE
ATTENTION ELECTRICIANS
available in: 43”/1092mm 50”/1270mm 60”/1524mm
LED Light Kit & Ceiling Extension Kit are oponal for all Aeratron™ models
AE2+ & AE3+ CEILING FAN
An isolaon switch per fan is highly recommended.
WARNING: If unusual oscillang movement is observed, immediately
stop using the ceiling fan and contact the naonal distributer/retailer.

!
Important information - Please read before attempting installation
1. Please read these instructions carefully, be mindful of all warnings and safety information
shown throughout this manual. Should you have any questions please call your local agent.
2. Please review the accompanying assembly diagrams before attempting installation.
3. This fan MUST be installed by a licensed & qualified electrician according to local authority
regulations and in accordance with current wiring rules of the country/state.
4. A copy of the purchasing receipt and proof of installation by a licensed and qualified electrician
according to local authority regulations is required for all warranty claims.
5. Where special access equipment is required to service the fan in accordance with local
authority regulations all associated costs are the responsibility of the owner.
6. Should a warranty claim be required, we reserve the right to charge a service fee for all call
outs where the fan is found not to be defective and / or where access is not provided.
7. To enable future programming, maintenance, cleaning and troubleshooting an isolation switch
per fan is highly recommended. Without an isolation switch per fan, an electrician maybe
required to assist with programming, maintenance, cleaning and troubleshooting. All
associated costs are the responsibility of the owner.
8. A Maximum of 8 fans on each RCD / circuit is recommended. The fans are a Class 5 Device
with leakage to Earth.
9. Your warranty will be void if a solid state dimmer or any other brand of wall controller is used.
10. The means for mains power disconnection must be incorporated in the fixed wiring in
accordance with national wiring rules.
11. To avoid possible electric shock during installation, be sure electricity is turned off at the main
power box before commencing work. Disconnect power by removing fuse or turning off circuit
breaker before installing the fan. Ensure all spliced connections are adequately insulated.
12. Warning! Do not allow the rotating fan blades to come into contact with any object, this can
cause serious injury or death.
13. Damage caused by incorrect installation, Force-majeure, lightning, electrical surges & spikes,
exposure to water, pests or moisture is not covered under warranty.
14. This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilies, or lack of experience and knowledge, unless they have been
given supervision or instrucon concerning use of the appliance by a person responsible for
their safety.
Australia, New Zealand: In accordance with AS/NZS60355-1 & ASNZS60355-2-80: “This
appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilies, or lack of experience and knowledge, unless they have been given
supervision or instrucon concerning use of the appliance by a person responsible for their
safety. Children should be supervised to ensure that they do not play with the appliance.”
1
This fan must be installed by a licensed and qualified
electrician according to local authority regulaons.

Contents
Important Information............................................................................................................................... 1
Contents................................................................................................................................................... 2
Unpacking your Fan ................................................................................................................................. 3
Installing your Fan .................................................................................................................................... 4
STEP1 Mounting the Hanger Bracket to Ceiling .................................................................................. 4
STEP 2 Connecting Mains Power to Terminal Block ........................................................................... 4
STEP 3 Inserting Fan Motor into Hanger Bracket ................................................................................ 5
STEP 4 Installing Receiver into Hanger Bracket................................................................................... 5
STEP 5 Connecting Receiver ............................................................................................................... 6
STEP 6 Pairing the Remote Control / Controlling the Fan.................................................................... 7
STEP 7 Attaching the Fan Motor Housing............................................................................................ 8
STEP 8 Assembling the Fan Blades .................................................................................................. 8,9
STEP 9 Attaching the Fan Blades ........................................................................................................ 9
Option A - LED Light Kit......................................................................................................................... 10
Option B - Ceiling Extension Kit............................................................................................................. 10
Option C - Raked Ceiling Kit .................................................................................................................. 11
Technical Specification .......................................................................................................................... 12
Care and Cleaning.................................................................................................................................. 13
Troubleshooting ..................................................................................................................................... 13
If the fan is noisy................................................................................................................................. 13
If the fan rotates but does not create much airflow............................................................................ 13
General Information................................................................................................................................ 14
Normal Wear and Tear........................................................................................................................ 14
Ceiling Fan Warranty .............................................................................................................................. 14
Transfer of Warranty ........................................................................................................................... 15
The following is NOT covered by warranty......................................................................................... 15
Aeratron ceiling fan warranty details ...................................................................................................... 16
2
For any problems found during fan installaon
please contact the naonal distributor/retailer and
ask for assistance before leaving the site.
IMPORTANT

3
Unpacking your fan
Unpack your fan and examine all parts, you should have the following:
NOTE: Wall control and Automaon control components are not included; please
contact your local fan supplier for more informaon.
TIMBER SCREWS X 2
PIVOT LOCK X1
HUB SCREWS X 10
MACHINE SCREWS X 2
WASHER X 2 WASHER X 2
HANGER BRACKET
MOTOR ASSEMBLY
CONTROL RECEIVER
REMOTE CONTROL
MOTOR HOUSING
AE3+ HUB UPPER
AE3+ HUB LOWER
AAA BATTERIES x2
AE2+ HUB UPPER
AE2+ HUB LOWER
FAN BLADE: AE2 x 2
AE3 x 3
OFF
LEARN
ON
CEILING SPACER x 2
OR
OR

STEP 1 Mounting Hanger Bracket to Ceiling
Before commencing installaon, turn off electricity
supply at the main power box. Disconnect power by
removing fuse or turning off circuit breaker.
!
Install hanger bracket to ceiling joist or Mounng Box embedded in concrete using the screws and washer
provided. Ensure ceiling joists are sound and of adequate size and strength to support a 35Kg (77lbs) load. If a
mber frame is to be added it must be securely nailed or screwed between two beams.Proper care must be
taken when mounng to concrete ceilings. For safe mounng these ceilings may require plasc plugs / anchors
and stronger screws.
WARNING: MOUNT ONLY TO AN OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT.
This fan is to be installed so that the blades are more than 2.3m above the floor
OPTION A:
Ceiling Joist
OPTION B:
Embedded
Mounng Box
STEP 2 Connecting Mains Power to Terminal Block
FROM HOUSE
(Mains Power)
TO RECEIVER
GREEN
BROWN L
NEUTRAL
LIVE
L
LIVE
BLUE N
LIVE
GROUND
N
L
4

Slide Remote Control Receiver
into Hanger Bracket from the
opposite side of the Terminal block
in the orientaon as shown above.
!
STEP 3 Inserting Fan Motor into Hanger Bracket
=
Ensure that lug on Hanger Bracket
is engaged in slot in suspension Ball
STEP 4 Installing Receiver into Hanger Bracket
5

6
STEP 5 Connecting the Receiver
2PIN
4PIN Receiver to Comms
(optional USE ONLY IF INSTRUCTED)
1. Connect the 2 PIN & 3 PIN connector
between DC Motor and Receiver.
2. Connect the 3PIN connector between
Mains Power and Reciever.
3PIN
Receiver to Motor
Aerial
Fix Remote Control
Aerial to ceiling
within circle of Fan
Motor Housing
Housing perimeter
3PIN
2PIN
Receiver to Light
LEARN SWITCH
ON RECIEVER
Aerial
OFF
LEARN
ON
3PIN Mains Power to Receiver
OFF
LEARN
ON

Pairing is always required during setup.
Note: “LEARN” switch on receiver.
7
STEP 6 Pairing the Remote Control
Controlling the Fan
1. Insert baeries
2. On Receiver: switch the “LEARN” switch to “ON”
3. Switch on the main power to acvate the receiver, indicated
by (one beep)
4. Within 60 seconds aer the power is turned on (one beep),
press the Fan “ON/OFF” buon and do not release (min. 3
secs) unl Fan receiver issues three “beeps” which indicates
successful pairing.
5. On Receiver: switch the “LEARN” switch to “OFF” (this will
lock the code with the remote)
6. Finish STEP 7, 8 & 9 before pressing ON/SPEED
buon to check for proper funconing
7. To re-pair, repeat steps 2 to 5
NOTE: Power must be off for 10 seconds
minimum before repairing.
The Remote Control and Fan Receiver will
memorise the set code for future use even if
mains power is switched off.
LIGHT SWITCH: Select ON/OFF or DIMMING for the light funcon.
(Light will maintain last seng if turned off)
1. Fan ON/OFF
2. Fan Speed UP/DOWN
2a. Fan Speed indicator 1-6
3. Forward / Reverse
3a. Use Forward mode (clockwise) for cooling
3b. Use Reverse mode (an-clockwise)
to circulate warm air
4. Light ON/OFF
4a. To DIM, press and HOLD light buon
to cycle from bright to dark.
(LIGHT SWITCH at DIMMING posion)
One Remote control can control up to 8 fans (within a 7m (23’) radius). On ALL receivers:
switch the “LEARN” switch to “ON”. Switch on the main power to acvate ALL receivers at
the same me, indicated by one ‘beep’ Within 30 seconds, press and hold the ON/OFF
buon on the remote control (min. 3 seconds) unl fan receiver issues three ‘beeps’.
Pairing a Single Fan per remote control: LEARN MODE
!
1
4
3b
2
2a
Pairing Mulple Fans per Remote Control
3
3a
4a
LIGHT SWITCH
LIGHT DIMMING
LIGHT ON/OFF

8
STEP 7 Attaching the Fan Motor Housing
Align the 3 tabs with the 3 holes on the
Housing and move upwards. Push tabs
inwards slightly before sliding upwards
unl you hear a click as the tabs lock.
STEP 8 Assembling the Fan Blades
A B
Place the Hub Upper onto a clean working area.
Line-up the two mounng holes in the Fan Blade
with the 2 holes in the Hub Upper. To ensure ght and secure blade assembly a
power tool on low torque seng (4-6) can
be used.
Fix the 3 Fan Blades ght and firm using 2 Hub
screws for each Blade.
Connues next page
CLICK!
Constantly handle fan with care at all mes to
avoid damaging the fan/surface
!

C
Lock Screw
9
STEP 9 Attaching the Fan Blades
44
STEP 8 Assembling the Fan Blades cont.
C D
Insert the Hub Lower (or oponal Light Hub
Lower) into the recess. With care, turn the fan
over.
Fasten the the Hub Lower from the top side
using the 3 Hub Screws.
No liability is accepted if the Silicone ring is
removed or the Pivot Lock is installed
incorrectly/lock screw is not ghtened.
Ensure fan sha is vercal.
The fan will be vercal if
the clearance ‘X’ between
the ceiling and motor
housing is equal all way
round.
!
Align Drive Sha with Pivot
Connector and slide fan
blades onto Drive Sha.
Hold/push up Fan Blades
and insert Pivot Lock,
defelecng the silicon
sideways. Push Pivot Lock
into the sha.
Tighten Lock Screw
securely using screw driver.
Do not use power tools.
D
x
A
Drive Sha
Pivot Connector
Silicone Ring
B
Pivot Lock
Silicone Ring
Light Hub Lower
(OPTIONAL)
Ce manuel convient aux modèles suivants
7
Table des matières
Autres manuels AerAtron Ventilateur

AerAtron
AerAtron AE+2 Series Manuel utilisateur

AerAtron
AerAtron FR3 Series Instructions d'installation et d'utilisation

AerAtron
AerAtron FR3 Series Instructions d'installation et d'utilisation

AerAtron
AerAtron AE2 Manuel utilisateur

AerAtron
AerAtron E502 Manuel utilisateur

AerAtron
AerAtron Ceiling Extension Manuel utilisateur