Multimeter Models 5212/5215/5217
Thank you for purchasing the AEMC Multimeter.
For best results from your instrument and for your safety, read the enclosed
operating instructions carefully and comply with the precautions for use. These
Measurement category IV corresponds to measurements taken at the
source of low-voltage installations.
Example: power feeders, counters and protection devices.
Measurement category III corresponds to measurements on building
installations.
Example:
industrial devices.
Measurement category II corresponds to measurements taken on
circuits directly connected to low-voltage installations.
Example: power supply to domestic electrical appliances and portable
tools.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Multimeter Models 5212/5215/5217
The protection obtained by the instrument can be compromised if it is used
in a way that is not recommended by the manufacturer. Carefully read and
understand all required precautions when using this instrument.
Failure to comply with these safety instructions can create a risk of electric shock,
manual, the protection provided by the instrument may be impaired.
Before using the instrument, make sure it functions properly by measuring a
known voltage, and check continuity by short-circuiting both test leads.
Do not use the instrument in an explosive atmosphere or in the presence of
Do not use the instrument on electrical networks with a rated voltage or
category higher than those listed for the instrument.
Respect the maximum rated voltages and currents between terminals and in
relation to ground/earth.
Do not use the instrument if it appears damaged, incomplete, or incorrectly
closed.
Before each use, check the condition of the insulation of the leads, the
instrument, and all accessories. Any insulation that appears damaged (even
partially) must be taken out of service for repair or disposal.
Use leads and accessories for voltage according to IEC 61010-031 and
measurement categories at least equal to those of the instrument. An
accessory with a lower category reduces the category of the combined
multimeter/accessory combination to that of the accessory.
Respect the environmental conditions of use listed in this manual.
opening the fuse access cover.
Do not modify the instrument or replace components using substitute parts.
® Instruments.
Replace the battery immediately if the symbol appears on the display.
Disconnect all leads before opening the battery access cover.
Use personal protection equipment when conditions require it.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Multimeter Models 5212/5215/5217
1.1 Receiving Your Shipment......................................................................5
1.2 Ordering Information.............................................................................5
1.2.1 Replacement Parts...................................................................5
1.3 Introducing the Models 5212, 5215 & 5217..........................................6
1.4 Front Panel ...........................................................................................8
1.5 LCD Screen ..........................................................................................9
1.6 Buttons ...............................................................................................10
1.7 Selection Dial......................................................................................10
1.8 Terminals ............................................................................................11
2.1 Setup ..................................................................................................12
2.1.1 Installing Batteries ..................................................................12
2.1.2 Mounting.................................................................................13
2.1.3 Instrument Check ...................................................................14
2.2 Measurement Options ........................................................................14
2.2.1 Manual Range and Auto Range .............................................15
2.2.2 Display Hold ...........................................................................15
2.2.3 Max-Min Spread (Models 5215 and 5217) .............................15
2.2.4 Relative Measurement (Models 5215 and 5217) ...................16
2.3 Operation............................................................................................16
2.3.1 Non-Contact Voltage Detection (NCV) ...................................17
2.3.2 Voltage Measurement.............................................................18
2.3.3 DC and AC Current Measurement..........................................19
2.3.4 Continuity Check ....................................................................20
2.3.5 Resistance Measurement.......................................................21
2.3.6 Diode Test...............................................................................22
2.3.7 Capacitance Measurement.....................................................23
2.3.8 Frequency & Duty Cycle Measurement (Model 5217)............24
2.3.9 Temperature Measurement (Model 5217) ..............................24
3.1 Reference Conditions .........................................................................25
........................................................................25
3.3 Measurement Resolution and Accuracy .............................................26
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Multimeter Models 5212/5215/5217
4.1 Battery Check .....................................................................................28
4.2 Cleaning..............................................................................................28
4.3 Testing and Replacing Fuses..............................................................28
4.3.1 Testing the 10A Fuse ..............................................................28
4.3.2 Testing the 630mA Fuse .........................................................29
4.3.3 Replacing a Fuse....................................................................29
4.4 Metrological Check and Calibration ....................................................30
4.5 Technical and Sales Assistance..........................................................30
4.6 Limited Warranty.................................................................................31
4.7 Warranty Repairs................................................................................31
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Multimeter Models 5212/5215/5217
1.
1.1
Upon receiving your shipment, make sure that the contents are consistent with the
packing list. Notify your distributor of any missing items. If the equipment appears
at once, giving a detailed description of any damage. Save the damaged packing
container to substantiate your claim.
1.2
...................................................................
...................................................................
...................................................................
Includes meter, soft carrying pouch, set of 2 color-coded leads (red/black), K-Thermocouple
adapter (Model 5217), two 1.5V AA batteries and a user manual.
1.2.1
Lead - Set of 2, 5 ft (1.5m) Color-coded (Red/Black) Silicone Leads,
Test Probes & Alligator Clips {Rated 1000V CAT IV}........................
MultiFix (universal mounting system) ...............................................
1.2.2
Soft Carrying Pouch .........................................................................
Lead - Set of 2, 5 ft (1.5m) Needle Tip Color-coded (Red/Black) w/4mm Right-angle
Plug {600V CAT IV w/shield on Needle Tip, 1000V CAT II w/o sheild}
..
K-Thermocouple w/4mm integrated adapter ....................................
Fuse - Set of 5, 10A, 1000V (Fast Blow), 30kA,
0.4 x 1.2" (10 x 30mm) .....................................................................
Fuse - Set of 5, 0.63A, 1000V (Fast Blow), 10kA,
0.25 x 1.26" (6.3 x 32mm) ................................................................
Check our Storefront at www.aemc.com for availability
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Multimeter Models 5212/5215/5217
The Digital Multimeter Models 5212, 5215, and 5217 measure electrical and
physical quantities, including:
AC and DC Voltage
AC and DC Current
Resistance and Continuity
Capacitance
Frequency and duty cycle (Model 5217)
Temperature (Model 5217)
The instrument can also perform continuity checks, voltage detection, and diode
testing (including forward bias voltage). Measurement features include Auto
Range mode, which enables the instrument to select the best range for the input
detected, and a Data Hold function.
The following table lists the various features respectively:
TRMS
LCD 4000 cts 6000 cts 6000 cts
NCV
VLowZ
VAC
VDC
mVAC
mVDC
AAC
ADC
mAAC
mADC
µAAC
µADC
Temperature °C & °F
Resistance
Diode test
Continuity
Capacitance
HOLD
Backlight
Flashlight
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Multimeter Models 5212/5215/5217
Auto Range
Max-Min
Frequency (Hz) and
Duty Cycle
Relative Measurement
Sleep Mode
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Multimeter Models 5212/5215/5217
Hz/%
µ
m
A
2
1
9
10
11
12
13
3
4
5
6
7
8
Figure 2-1 (Model 5217 Shown) aaaaa
The instrument front panel consists primarily of an LCD display, a rotary mode
1"Flashlight" LED Common input terminal
2LCD display Range button
Function (yellow) button
Sleep mode enable/disable
Relative Measurement button
(Models 5215/5217)
HOLD button
Short press: Holds measurement
Long (>2s) press: turns on back- 11 Frequency/duty cycle button
(Model 5217)
Maximum/Minimum button
(Models 5215 and 5217) 12 µ/mA current input terminal
(Models 5215/5217)
Measurement selection dial Voltage input terminal
10A current input terminal
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com
Ce manuel convient aux modèles suivants
2
Autres manuels AEMC instruments Multimètre
Manuels Multimètre populaires d'autres marques

Gossen MetraWatt
Gossen MetraWatt METRAmax 6 Manuel utilisateur

PeakTech
PeakTech 4000 Manuel d'utilisation et d'entretien

YOKOGAWA
YOKOGAWA 90050B Manuel utilisateur

Gossen MetraWatt
Gossen MetraWatt METRALINE DMM16 Manuel utilisateur

Fluke
Fluke 8846A Manuel d'utilisation et d'entretien

Tempo Communications
Tempo Communications MM200 Manuel utilisateur