TS100/TS200 Series PA Speakers
SM70 Installation and Operation Manual
April 16, 2012 Rev: 5.00 Page 2-2
ENG-FORM: 805-0100.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
2.3.2 Cautions
Do not operate the equipment in a hangar or in confined areas.
Do not operate the equipment with snow, water or other foreign matter in the loudspeaker horn.
Do not clean the loudspeaker with compressed air.
Be careful only to operate the siren for 3 cycles at a time and trill for a short 2 to 3 second burst. The
driver is unable to withstand constant signals –it requires a Duty cycle (see above) to permit the unit to
cool down.
2.3.3 Cabling and Wiring
All unshielded wire shall be selected in accordance with AC43.13-1B Change 1, Paragraphs 11-76
through 11-78. Wire types should be to MIL-W-22759 as specified in AC43.13-1B Change 1, Paragraphs
11-85, 11-86, and listed in Table 11-11.
For shielded wire applications, use Tefzel MIL-M-27500 or MIL-M-81044 shielded wire with solder sleeves
(for shield terminations) to make the most compact and easily terminated interconnect. Follow the wiring
diagrams in Section 2.5 as required.
2.3.4 Mechanical Installation
The installing agency is responsible for the design, engineering and installation of the mounting bracket
for the Speaker. Careful consideration should be given to the operating environment and the mechanical
forces acting upon the unit.
When installing the speakers, ensure that there is adequate airflow to cool the speaker drivers,
and that the speaker phasing is correct.
Note: The speakers are designed for intermittent operation only.
CAUTION
Failure to install the TS200WR speakers as shown in the relevant
wiring diagram(s) will result in PERMANENT AND IRREPARABLE
DAMAGE to the speaker drivers.
Both speaker drivers MUST be wired in phase to ensure proper
performance and to prevent damage.
2.3.5 Post-Installation Checks
Ensure all connectors are tight and the mechanical installation is sound.
When the PA system installation is complete, carry out a full performance test to ensure that all
components of the system (including the speaker) are functioning correctly. For full post-installation
check information, refer to Section 2 of SM35, PA110/220 High Power Audio Amplifiers Service manual.