ADT 6270ADT Manuel utilisateur

$
$'
'7
7
7
7R
RX
XF
FK
K
6
6F
FU
UH
HH
HQ
Q
.
.H
H\
\S
SD
DG
G
,QVWDOODWLRQDQG
6HWXS*XLGH
ARMED
READY
MESSAGE
FUNC PANIC BACK
HOME
K0977-2 9/03 Rev. A


iii
Table of Contents
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
SECTION 1 –General Information.............................................. 1–1
About the 6270ADT......................................................................... 1–1
System Features .............................................................................. 1–1
Security......................................................................................... 1–1
Setup............................................................................................. 1–1
Compatibility ................................................................................... 1–2
ECP Error......................................................................................... 1–2
SECTION 2 –Mounting and Wiring ............................................ 2–1
Mounting the 6270ADT................................................................... 2–1
Wiring the 6270ADT ....................................................................... 2–2
SECTION 3 –Front Panel LEDs and Buttons........................... 3–1
Front Panel LEDs............................................................................ 3–1
Front Panel Buttons ........................................................................ 3–2
SECTION 4 –Initial Setup............................................................. 4–1
Programming the Control Panel..................................................... 4–1
6270ADT Initialization.................................................................... 4–2
Power Up ...................................................................................... 4–2
How to Change the ECP Address ................................................... 4–2
How to Access the Central Station Screen..................................... 4–3
How to Select System Options .................................................... 4–6
How to Set the NIGHT Setup Button Function......................... 4–7
How to View and Edit Screen Security....................................... 4–8
How to View the Panel Configuration ........................................ 4–9
6270ADT Setup.............................................................................. 4–10
How to Adjust the Touch Screen Contrast ............................... 4–11
How to Adjust the Volume......................................................... 4–12
How to Select Screen Saver Activation Time........................... 4–13
How to Set the Time and Date.................................................. 4–14
Setting Chime Mode On/Off.......................................................... 4–15
SECTION 5 –User Codes................................................................ 5–1
Introduction to User Code Setup .................................................... 5–1
How to Access User Setup............................................................... 5–1
How to Add a User ....................................................................... 5–3
How to Delete a User................................................................... 5–5
How to Edit a User....................................................................... 5–6
SECTION 6 –Maintenance ............................................................ 6–1
About 6270ADT Maintenance......................................................... 6–1

iv
How to Clean the 6270ADT ............................................................ 6–1
Routine Care .................................................................................... 6–3
SECTION 7 –Troubleshooting...................................................... 7–1
Troubleshooting ............................................................................... 7–1
Diagnostics....................................................................................... 7–1
About Diagnostics ........................................................................ 7–1
How to Access the Diagnostics .................................................... 7–1
Performing Diagnostics................................................................... 7–3
LCD Display Test......................................................................... 7–3
Audio Test..................................................................................... 7–6
LED Test....................................................................................... 7–7
SECTION 8 –Specifications .......................................................... 8–1
Specifications ................................................................................... 8–1
SECTION 9 –Index.......................................................................... 9–1

v
Conventions Used in This Manual
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Before you begin using this manual, it is important that you
understand the meaning of the following symbols (icons) and text
note.
ULThese notes include specific information that must be followed if you are
installing this system for a UL Listed application.
These notes include information that you should be aware of before
continuing with the installation, and which, if not observed, could result
in operational difficulties.
Note: These text notes are provided throughout the manual to provide
informative information and shortcut tips for the installer.

vi

1–1
SECTION 1
General Information
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
In This Section
♦
About the 6270ADT
♦
System Features
♦Compatibility
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
About the 6270ADT
The 6270ADT is an intuitive, graphical touch-screen keypad that
combines security and home control. The 6270ADT can be used for:
x
Quick and easy security system operation
x
Messages
x
Control of the home environment, including lights and contains
provisions for the future control of heating and air-conditioning.
ULThe home environment control feature has not been evaluated by UL.
System Features
Security
x
Arm System
–Away
–Stay
–Night
x
Disarm System
x
User Codes - Allows authorized user to add or delete codes
x
Bypass Zones
Setup
x
Volume
x
Contrast

6270ADT Installation and Setup Guide
1–2
x
Diagnostics
x
Keypad Emulation
Compatibility
The below listing identifies the alarm systems that the 6270ADT can
interface with, the maximum number of 6270ADTs that can be used
with each system, and the minimum alarm panel software revision
level for compatibility.
MAXIMUM NUMBER MINIMUM SOFTWARE
ALARM SYSTEM OF 6270ADTs REVISION LEVEL
Safewatch Pro 3000EN 2 All Levels
VISTA-128BPADT 3 2.4
VISTA-250FBPADT 1 1.5
VISTA-15P 2 3 (When available)
VISTA-20P 2 3 (When available)
VISTA-20PS 2 All Levels
VISTA-128BP 3 2.4
VISTA-128FBP 3 1.6
VISTA-250BP 3 2.4
VISTA-250FBP 1 1.5
On all panels except the residential panels, you may obtain the software
revision level of the alarm panel by entering the program mode and then
entering #92 on the keypad. The second line of the keypad displays the
software revision level (without the decimal point).
ECP Error
The message “ECP Error”will be displayed at the top of the screen (except for
the Home screen) when the 6270ADT cannot communicate with the alarm
panel. This may be caused by and incorrect ECP address in the 6270ADT or
because AUI type devices have not been enabled in the panel. While this
message is being displayed, you must use the 6270ADT default code of “4140”
any time the 6270ADT requests an authorized code.

2–1
SECTION 2
Mounting and Wiring
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
In This Section
♦
Mounting the 6270ADT
♦
Wiring the 6270ADT
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Mounting the 6270ADT
The 6270ADT should be mounted using the following criteria:
x
The 6270ADT must be mounted indoors, and
x
should be mounted at eye level for easy viewing by the user.
To mount the 6270ADT, see Figure 1 and complete the following
steps:
1. Detach the case back by pushing up into the two tabs located at
the bottom of the 6270ADT with the blade of a screwdriver while
pulling the case back and case front apart.
2. Locate the case back over the mounting surface such that the
opening in the case back is aligned with the wire/cable access
opening (in the mounting surface) while passing the wires/cable
through the opening in the case back.
3. Secure the case back to the mounting surface using four screws
(supplied).
Prior to attaching the case front to the case back, be sure to wire the
6270ADT as described in the "
Wiring the 6270ADT
" paragraph in this
section.

6270ADT Installation and Setup Guide
2–2
MOUNTING
SCREWS (4)
(TYP)
WALL OR
MOUNTING
SURFACE
CASE
FRONT
CASE
BACK
6270-003-V1
ARMED
READY
MESSAGE
ARMED
HOME FUNC PANIC BACK
Figure 1. Mounting the 6270ADT
Wiring the 6270ADT
Connect 6270ADT in parallel with keypads and other peripheral
devices using the keypad data (ECP) bus. To wire, see the Summary
of Connections diagrams at the back of this guide, or the appropriate
Systems Interconnection Diagram provided, and follow the
instructions below.
UL
x
On single partition systems, at least one keypad MUST receive
power from the control panel’s auxilary power.
x
On multiple partition systems, at least one keypad in each partition
MUST receive power from the control panel’s auxilary power.
x
You may use a Listed Class 2 power supply suited for the appli-
cation to power additional keypads.
Unshielded 4-conductor cable is recommended for the power/data wire.
Table des matières
Autres manuels ADT Écran tactile
Manuels Écran tactile populaires d'autres marques

IBASE Technology
IBASE Technology ASTUT-152-RE1S Manuel utilisateur

YASKAWA
YASKAWA TP 610C Manuel utilisateur

B&R
B&R Power Panel C Series Manuel utilisateur

Beijer Electronics
Beijer Electronics X2 control Manuel utilisateur

AXIOMTEK
AXIOMTEK GOT321W-521 Manuel utilisateur

TRIDONIC.ATCO
TRIDONIC.ATCO x-touchBOX Manuel utilisateur