Adleepower MS Series Manuel utilisateur

ADLEEPOWER
INSTRUCTION MANUAL
GENERAL-PURPOSE INVERTER
THANK YOU VERY MUCH FOR YOUR PURCHASE
OF ADLEE INVERTER MS SERIES.
PLEASE READ THIS INSTRUCTION MANUAL
BEFORE INSTALLATION OF THE INVERTER.
R
MS2 / MS4

PREFACE
This general-purpose inverter made by ADLEE Powertronic., Ltd.
Read this instruction manual throughly before operation.
This manual will be helpful in the installation, parameter setting, trouble-
shooting, and daily maintenance of the AC motor drives. To guarantee
safe operation of the equipment, read the following safety guidelines
before connecting power to the AC drives. Keep this operating manual
handy and distribute to all users for reference.
A. General Precaution
1. There are some covers and shields on this inverter.
Make sure all covers and shields are replaced befor operating this
product.
2. This manual may be modified when necessary because of improve-
ment of the product or changes in specification.
3. Contact your ADLEE representative to order a copy of this manual,
if your manual has been damaged or lost.
4. ADLEE is not responsible for any modification of the product made
by the user, since that will void your guarantee.
B. Safety symbols
Symbols which may appear on the manual
WARNING
Indicates a potentially hazardous situation
which, if not avoided, could result in death
or serious injury to personnel.
CAUTION
Indicates a potentially hazardous
situation which, if not avoided, may
result in minor or moderate injury to
personnel and damage to equipment.
- I -
!

RECEIVING
CAUTION
* Do not install or operate the driver which is damaged or has missing
parts.
Failure to observe this caution may result in personal injury or
equipment damage.
INSTALLATION
CAUTION
* Lift the cabinet by the base. When moving the unit, never lift by the
front cover.
Overwise, the main unit may be dropped causing damage to the
unit.
* Mount the driver on nonflammable material. (i.e. metal)
Failure to observe this caution can result a fire.
* When mounting units in an enclosure, install a fan or other cooling
device to keep the intake air temperature below 45℃.
Overheating may cause a fire or damage to the unit.
INSTALLATION
WARNING
* Only commence wiring after verifying that the power supply is
turned OFF.
Failure to observe this warning can result in an electrical shock or a
fire.
* Wiring should be performed only by qualified personnel.
Failure to observe this warning can result in an electrical shock or a
fire.
* Make sure to ground the ground terminal.
Ground resistance : 100 Ohm or less.
Failure to observe this warning can result in an electrical shock or a
fire.
- II -
!

CAUTION
* Verify that the driver rated voltage coincides with the AC power
supply voltage.
Failure to observe this caution can result in personal injury or a fire.
* Do not perform a withstand voltage test of the driver.
It may cause semi-conductor elements to be damaged.
* To connect a braking resistor, follow in APPENDIX A.
Improper connection may cause the unit damaged or a fire.
* Tighten terminal screws.
Failure to observe this caution can result a fire.
* Never connect the AC main circuit power supply to output terminals
W, V and U.
The inverter will be damaged and invalidate the guarantee.
OPERATION
WARNING
* Only turn ON the input power supply after replacing the front cover.
Do not remove the cover while current is flowing.
Failure to observe this warning can result in an electrical shock.
- III -

CAUTION
* Since it is easy to change. operation speed from low to high speed,
verify the safe working range of the motor and machine before op-
eration.
Failure to observe this caution can result in personal injury and
machine damage.
* Do not change signals during operation.
The machine or the inverter may be damaged.
* All the constants of the inverter have been preset at the factory.
Do not change the settings unnecessary.
WARNING
* Never touch high-voltage terminals in the driver.
Failure to observe this warning can result in an electrical shock.
* Replace all protective covers before powering up the inverter.
To remove the cover, make sure to shut OFF the molded-case circuit
breaker.
Failure to observe this warning can result in an electrical shock.
* Perform maintenance or inspection only after verifying that the
CHARGE LED goes OFF, after the main circuit power supply is
turnned OFF.
The capacitors are still charged and can be dangerous.
* Only authorized personnel should be permitted to perform mainte-
nance, inspections or parts replacement.
Failure to observe this warning can result in an electrical shock.
MAINTENANCE AND INSPECTION
- IV -
!

CAUTION
* The control PC board employs CMOS ICs. Do not touch the CMOS
elements by hand.
They are easily damaged by static electricity.
* Do not connect or disconnect wires or connectors while power is
applied to the circuit.
Failure to observe this caution can result in personal injury.
OTHERS
WARNING
* Never modify the product.
Failure to observe this warning can result in an electrical shock or
personal injury and will invalidate the guarantee.
- V -

CONTENTS
1. RECEIVING
2. SPECIFICATIONS
3. DIMENSION DRAWINGS
4. INSTALLATION
5. DESCRIPTION OF TERMINALS
6. DIGITAL OPERATION PANEL .
7. FUNCTIONS DESCRIPTION
8. DISPLAY ERROR CODES
9. PRECAUTIONS
10. TROUBLESHOOTING
11. APPLICATION
12. INVERTER SELECTION
13. APPENDIX
A. Optional braking resistor
B. Terminal wiring diagram
C. Remote operator
D. Optional parts
1
2
4
8
9
20
21
81
85
86
87
91
93
93
94
95
96

1. RECEIVING
This MS series AC drive has gone through rigorous quality control tests
at the factory before shipment. After receiving the AC drive, please check
for the following :
(1) No damage is found on each product after shipping.
(2) The product is as ordered (check the nameplate, voltage and fre-
quency).
(3) A set of inverter unit and instruction manual is contained in the
package.
For any irregularity, contact the sales shop where you purchased
immediately.
(4) Description of name plate
1
MODEL : MS 2 - 115
Max Applicable motor(4 pole)
Single Phase :
102 : 0.2KW 104 : 0.4KW 107 : 0.75KW
115 : 1.5KW 122 : 2.2KW 137 : 3.7KW
3 Phase :
307 : 0.75KW 315 : 1.5KW 322 : 2.2KW
337 : 3.7KW
MS series
Voltage class :
1 : 110V
2 : 220V
4 : 380/440V

2. SPECIFICATIONS
2
PROG
±±
±
ψψ
ψψ
Model MS1 MS2
Voltage 1 110VAC 10% 1220VAC 10%
Model No MS1-104 MS2-102 MS2-104 MS2-107 MS2-115 MS2-122 MS2-137
Input Frequency 50HZ~60HZ10%
Output Voltage 3 110VAC 3 220VAC
Output Frequency 0.5 ~ 1200HZ
Output
Rated current (A) 4.1 A 1.4 A 2.5 A 4.1 A 7 A 10 A 16 A
Capacity (KVA) 0.8 KVA 0.6 KVA 1.0 KVA 1.6 KVA 2.7 KVA 3.8 KVA 6.1 KVA
Largest motor
KW ( 4 poles ) 0.4 KW 0.2KW 0.4KW 0.75KW 1.5KW 2.2KW 3.7KW
Control Sine wave pulse width modulation
Braking Regenerative discharge braking
Over current
Capacity 150% of rated current ( 1 minute)
Acceleration time 0.1 ~ 6000 SEC
Deceleration time 0.1 ~ 6000 SEC
Frequency
setting
Digital Use keyboard for setting and confirm by
Analog By frequency knob
Display type LED Digits
Cooling Method Self-cooled Self-cooled Self-cooled Self-cooled Air-cooled Air-cooled Air-cooled
Dimension drawing Fig 1 Fig1 Fig 1 Fig 1 Fig 2 Fig 2 Fig 3
Weight ( NW . KG ) 1.2KG 1.2KG 1.2KG 1.3KG 1.3KG 1.4KG 4.0 KG

PROG
3
ψ
ψ±
±
Model MS4
Voltage 3380/440VAC 10%
Model No MS4-307 MS4-315 MS4-322 MS4-337
Input Frequency 50HZ~60HZ10%
Output Voltage 3 380/440VAC
Output Frequency 0.5 ~ 1200HZ
Output
Rated current (A) 2.5 A 4 A 6 A 9 A
Capacity (KVA) 1.9 KVA 3.1 KVA 4.2 KVA 6.9 KVA
Largest motor
KW ( 4 poles ) 0.75 KW 1.5KW 2.2KW 3.7KW
Control Sine wave pulse width modulation
Braking Regenerative discharge braking
Over current
Capacity 150% of rated current ( 1 minute)
Acceleration time 0.1 ~ 6000 SEC
Deceleration time 0.1 ~ 6000 SEC
Frequency
setting
Digital Use keyboard for setting and confirm by
Analog By frequency knob
Display type LED Digits
Cooling Method Air-cooled Air-cooled Air-cooled Air-cooled
Dimension drawing Fig 4 Fig 4 Fig 4 Fig 3
Weight ( NW . KG ) 1.3KG 1.3KG 1.4KG 4.0 KG
Ce manuel convient aux modèles suivants
15
Table des matières
Autres manuels Adleepower Onduleur