Addvent AVAC9000 Schéma de câblage

IMPORTANT SAFEGUARDS
WHEN USING ANY ELECTRICAL APPLIANCE, BASIC SAFETY
PRECAUTIONS SHOULD ALWAYS BE FOLLOWED.
PLEASE READ ALL INSTRUCTIONS CAREFULLY
AND RETAIN FOR FUTURE REFERENCE
AVAC9000
Portable Air Conditioner
Installation Instructions
User Guide

2
BEFORE USE
These symbols on your device mean:
This appliance is lled with Propane gas R290. Follow strictly the
manufacturer’s instruction concerning use and repairs!
Before using the machine, read carefully the entire instruction manual.
Do not install, operate or store the device in a room smaller than 11m
2
.

3
Safety Instructions
This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved.
Cleaning and user maintenance shall not be made by children without
supervision.
Children of less than 3 years old should be kept away unless continuously
supervised.
Children aged from 3 years and less than 8 years shall only switch on/off
the appliance provided that it has been placed or installed in its intended
normal operating position and they have been given supervision or
instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children aged from 3 years and less than 8 years shall
not plug in, regulate and clean the appliance or perform user maintenance.
Never use this appliance for anything other than its intended purpose.
Your air conditioner is designed to be used in a house, ofce and similar
conditions and should not be used for any other purpose.
If the supply cord is damaged, it must be replaced by a suitably qualied
person in order to avoid a hazard.
Always keep the unit in an upright position to avoid damage to the cooling
system.
Be sure that the air inlets and outlets are not blocked or covered.
Don’t put any object into the air inlet or outlet of the unit.
In order to avoid overheating, do not cover the unit while it is plugged in or
in-use.
Never connect the unit to a defective socket.
Never locate the appliance immediately below a socket-outlet.
Never unplug the air conditioner while it is operating. This could damage
the electronic circuits.
Leave at least 300mm space around the unit.
To avoid tripping the circuit, do not use an extension cord for this unit.
WARNING

4
To turn on your unit, insert the plug into the socket and press the
power button.
Do not bend or crush the exhaust hose.
Do not place the power cord under a carpet.
This appliance is for ordinary indoor use. Never use the appliance in
the immediate surroundings of a bath, a shower, a swimming pool or a
greenhouse.
Keep the appliance in the vertical position during transportation. After
unpacking, place the unit upright to allow the refrigerant to stabilise, and
wait 3 hours before use.
Any damage resulting from failure to comply with these instructions is
excluded from the warranty. Do not install and use your air conditioner
before completely reading these instructions.
CAUTION: Dispose of packaging material safely according to local regulations

5
SAFETY RELATING TO REFRIGERANT R290
Read these warnings carefully.
This appliance contains the refrigerant R290. R290 is a refrigerant that
complies with the relevant European Directives. Never perforate the
refrigerant circuit. R290 is ammable (GWP3)!
Do not use means to accelerate the defrosting process or to clean, other
than those recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating
ignition sources (for example: open ames, an operating gas appliance or an
operating electric heater).
Do not pierce or burn any of the components of the cooling circuit of the
unit. Do not set light to the unit.
The appliance shall be stored so as to prevent mechanical damage from
occurring.
Appliance should be installed, operated and stored in a room with a oor
area larger than 11m
2
.
Be aware that the refrigerants may not contain an odour, which means you
cannot smell leaks..
Compliance with national gas regulations shall be observed.
Keep ventilation openings clear of obstruction.
A warning that the appliance shall be stored in a well-ventilated area where
the room size corresponds to the room area as specied for operation.
Any person who is involved with working on or breaking into a refrigerant
circuit should hold a current valid certicate from an industry-accredited
assessment authority, which authorises their competence to handle
refrigerants safely in accordance with an industry recognised assessment
specication.
Servicing shall only be performed on the grounds as recommended by the
equipment manufacturer. Maintenance and repair requiring the assistance
of other skilled personnel shall be carried out under the supervision of the
person competent in the use of ammable refrigerants.

6
Components
1. Control panel
2. Carrying handle
3. Air outlet
4. Air lter
5. Exhaust air outlet
6. Air lter
7. Water stopper/
drainage point
8. Air inlet
9. Cord storage
10. Air inlet
Accessories
11. Exhaust hose
12. Flat Type Adaptor - for insertion over
hose & connected with PVC window kit
(or into hole in the wall/window).
13. I nward adaptor (connected unit &
exhaust hose)
14. PVC Window Kit 1 - for lling the open
window space
15. PVC Window Kit 2 - for lling the open
window space
16. PVC Window Kit 3 - for lling the
open window space and with hole for
connection to exhaust hose.
17. Drain tube for continuous drainage
18. Active carbon lter
19. Remote control
2
7
1
310
9
8
4
5
6

7
Installation
1. Offer the extendable slides to the window gap and adjust the length as you need.
2. Feed exhaust hose through the slide and slide window across so that spacer
is held securely. This technique may also be used for sash windows.
3. Note! Take care to maintain protection against intruders
Before using your air conditioner, you will need to install the exhaust hose so that
the heat (hot air) from the appliance are released onto an outside, open-air area.
To install the exhaust hose, feed the end of the hose through any available
window and secure it into place using the included adapter. Ensure the distance
between the unit and the window is at least 50cm.
To seal the gap around the adapter, you may utilize the extendable slides
(supplied along with the appliance) as below:
• Using the extendable slides

8
Mounting of the exhaust hose
Use only the hose provided
and attach exhaust hose
to the back of the air
conditioner.
FIG. 7
FIG. 10
WARNING!
The length of the exhaust hose
is specially designed according
to the specication of this
product. Do not replace or
extend it with an alternative
hose as this could cause the
unit to malfunction.
FIG. 9
The hose may be extended
from 300mm to 1500mm
but for maximum efciency
use the shortest length
possible.
FIG. 8
Avoid kinks and bends in
the exhaust hose as this will
cause expelled moist air to
build up causing the unit to
overheat and shut down.
Fig 7 & 8 show correct
position.

9
Installation of the carbon lter
1. Remove the lter frame from the unit.
2. Remove the active carbon lter from
its plastic bag.
3. Insert the active carbon lter into the
back of the unit.
4. Re-t the lter frame inside the unit.
FIG. 11
FIG. 12

10
Operation
Control panel
1. ON/OFF (power) button
2. Mode (function) option
button
3. Speed (ventilation)button
4. “Timer” button
5. ‘Temperature down ‘ button
6. ‘Temperature up’ button
7. “Sleep” button
a. Display window
b. Receiver for remote control
c. High ventilation indicator
d. Low ventilation indicator
e. Automatic mode indicator
f. Cooling mode indicator
g. Fan mode indicator
h. DEHUMIDIFY(DRY) mode
indicator
i. “Full Water” indicator
j. Indicator for compressor
operation
Adjust the air vent
Before using the unit, please open the horizontal louvers. Adjust the louvers to
your desired direction.
FIG. 13
Autres manuels pour AVAC9000
1
Table des matières
Autres manuels Addvent Climatiseur