ADAMS RITE eForce 150 Instructions de montage

1 80-0180-307, Rev A
eForce
®
150 Keyless Entry
Model 3090
Installation Instructions and User’s Guide

2 80-0180-307, Rev A

3 80-0180-307, Rev A
TABLE OF CONTENTS
TABLE OF CONTENTS............................................................................3
INSTALLATION.........................................................................................5
Important Notes.....................................................................................5
Tools and Equipment Needed...............................................................5
Supplied Parts.......................................................................................6
Preparing the Door................................................................................6
Preparing the Spindle............................................................................8
Configuring the Model 3090 for Lock Series.........................................9
Handing the eForce 150......................................................................11
Installing the Mortise Cylinder.............................................................12
Mounting the eForce 150....................................................................14
Installing the eForce 150 Batteries .....................................................15
SETTING UP AND USING THE eFORCE 150.......................................16
General Information ............................................................................16
Programming Information....................................................................17
Speed Mode........................................................................................17
User Code Descriptions......................................................................18
Features and Options Descriptions.....................................................19
Programming the User Codes.............................................................20
Master Code....................................................................................20
Reset Master Code .........................................................................21
Emergency Code ............................................................................21
Supervisor Code..............................................................................22
Lockout Code..................................................................................23

4 80-0180-307, Rev A
Passage Code.................................................................................24
Normal User Codes.........................................................................24
One Time User Codes ....................................................................25
Programming Features and Options...................................................26
Delete All User Codes.....................................................................26
Delete Supervisor, Lockout, Passage, or a Single Normal User
Code................................................................................................26
Delete a Block of Normal User Codes ............................................27
Reset All Features to Default Values..............................................28
Set Audible Keypad Feedback........................................................28
Set Visual Keypad Feedback..........................................................29
Set Number of Successive Invalid User Code Entries Accepted....29
Set Error Lockout Time...................................................................30
Set Hold-Open (Unlock) Time.........................................................30
Set Emergency Hold-Open (Unlock) Time......................................31
Replacing the eForce 150 Batteries....................................................31
Replacing the Mortise Cylinder...........................................................33
TROUBLESHOOTING............................................................................37
Green light comes on, but lever will not retract latch-bolt...............37
No lights come on when pushbuttons are depressed.....................37
No tones sound when pushbuttons are depressed.........................37
Factory default codes not working. .................................................37
User codes not working...................................................................37
Operator stays unlocked.................................................................37
WARRANTY............................................................................................38
eFORCE 150 USER LOG.......................................................................39

5 80-0180-307, Rev A
INSTALLATION
Important Notes
The 3090-01 is designed exclusively for latching hardware including:
• Adams Rite 4500/4900 deadlatches
• Adams Rite 8000 series exit devices
• Yale 7200 series narrow stile exit devices
• Corbin Russwin ED4000 series
The 3090-02 is compatible with Adams Rite MS®Series Deadbolts only!
These units are not interchangeable. These instructions, and the
fasteners supplied, apply to metal door applications. Other door types
will need fasteners designed for the given medium.
IMPORTANT: This product must be installed according to all
applicable building and life safety codes!
Tools and Equipment Needed
The following common hand tools are needed for installation:
• Center punch
• Drill gun
• 1/4” [6.35 mm] drill bit
• Phillips screwdriver
• Pliers
• Flat tip screwdriver
• Pencil
The following additional equipment is needed:
NOTE: 1-1/2” cylinders require a 1/8” trim ring.
• Mortise Cylinder - 1” to 1-1/2” in length range with MS cam

6 80-0180-307, Rev A
Supplied Parts
NOTE 1: Figure 1 illustrates the supplied parts.
NOTE 2: A cam plug is supplied for either the 3090-01 or 3090-02.
Item Description Quantity
1 Mounting Bracket (Part Number 22-9076) 1
2 #10-32 x 5/8” Phillips Pan Head Screws with lock washer 4
3 Spindle (Part Number 22-9154) 1
4 5/64” Allen Key 1
5 Cylinder Locking Ring (Part Number 24-0061) 1
6 Locking Ring Spanner Tool (Part Number 22-0594) 1
Figure 1
Preparing the Door
NOTE: Template 80-0180-396-01 is used for Yale, Corbin Russwin
and SARGENT exit devices (see Figure 2).
1. SELECT the stick-on template to match the application.
2. MARK the backset and horizontal centerlines.
3. APPLY clear template over the centerline marks (see Figure 2).
4. CENTER-PUNCH the four (4) referenced mounting holes, and
REMOVE template.
5. DRILL holes at center-punch locations using a 1/4” [6.35 mm] drill
bit.
6. INSTALL Rivnuts according to instructions supplied in Rivnut kit.

7 80-0180-307, Rev A
7. INSTALL the mounting bracket with two (2) #10-32 x 5/8” pan head
screws (see Figure 3, “Installing the Mounting Bracket”).
Figure 2
Figure 3

8 80-0180-307, Rev A
Preparing the Spindle
NOTE 1: Steps 1–2 are performed for Adams Rite MS1850 Deadbolts,
4500/4900 Deadlatches, and 8000 Series Mortise Exit
Devices.
NOTE 2: One notch is added for a 2” thick door.
1. SNAP OFF the spindle at the fifth (5th) notch (see Figure 4).
2. INSERT the flat end into the exit device.
Figure 4
NOTE 1: Steps 3–4 are performed for Adams Rite 8600 Concealed
Vertical Rod Exit Devices.
NOTE 2: Two (2) notches are added for a 2” thick door.
3. SNAP OFF the spindle at the sixth (6th) notch (see Figure 5).
4. INSERT the flat end into the exit device.
Figure 5
NOTE 1: Steps 5–6 are performed for Adams Rite 8000 Series Surface
Vertical Rod and Rim Exit Devices, Yale 7200 Series Narrow
Stile Exit Devices, and Corbin Russwin ED4000 Series Exit
Devices.
NOTE 2: Two (2) notches are added for a 2” thick door.
5. SNAP OFF the spindle at the fourteenth (14th) notch (see Figure 6).
6. INSERT the “T” end into the exit device.
Figure 6

9 80-0180-307, Rev A
Configuring the Model 3090 for Lock Series
NOTE: Steps 1–3 are performed to configure a Model 3090-01 for a
mortise latch application using 4500/4900 Deadlatches
(including 8300/8400 Exit Devices).
1. CONFIGURE the supplied cam plug to match the hand of door (see
Figures 7 and 8).
2. INSERT cam plug into latch case with notch on the cam plug aligned
with latch case set screw.
3. TIGHTEN set screw and SECURE with the two brass cam plug
screws (see Figure 9).
Figure 7 Figure 8 Figure 9
NOTE: Steps 4–5 are performed to configure a Model 3090-01 for a
CVR exit device application using 8500/8600 Exit Devices.
4. INSTALL tailpiece adapter on the vertical rod.
5. FASTEN with Phillips screw (see Figure 10)
Figure 10

10 80-0180-307, Rev A
NOTE: Step 6 is performed to configure a Model 3090-01 for a RIM
exit device using 8700/8800 Exit Devices.
6. On the back side of the exit device, REMOVE only the lower Phillips
head screw, depending on hand of door, to free up the cylinder
actuator for use (see Figure 11).
Figure 11
NOTE: Steps 7–8 are performed to configure a Model 3090-02 for a
MS 1850 application using a MS®series Deadbolt.
7. For MS Deadbolt, INSERT cam plug into lock case ensuring the
notch on the cam plug is aligned with lock case set screw.
NOTE: Cam Plug must be positioned below door surface.
8. TIGHTEN set screw and SECURE with the two (2) brass cam plug
screws (see Figure 12).
Figure 12