GENERAL INFORMATION
YOUR ACTRONAIR ESP ULTIMA SYSTEM IS A STATE OF THE ART PRODUCT with
advanced Microprocessor Control that automatically controls and regulates conditioned air in
each zone to provide year-round climate control and comfort.
INSIDE THIS MANUAL You will find instructions for Zone Controller used with ActronAir ESP
Ultima system. Functions of the Master Controller, LM7-D and LM24W in conjunction with ESP
Ultima operation, are also explained.
NOTE: Basic and detailed functions of the Master Controller, LM7-D and LM24W,
are explained in the operation manual (0500-121) supplied with your A/C unit.
ACTRONAIR ESP ULTIMA SYSTEM is a highly advanced and efficient VAV system that lets
you control the temperature of each zone. It is also used in conjunction with ECM (Electronically
Commutated Motor) Indoor fan and ActronAir ESP digital compressor technology for maximum
energy savings and comfort.
IMPORTANT To ensure efficient and proper operation of your equipment, read and understand
all instructions contained in this manual and the Master Controller Manual. Failure to do so may
result in damage of equipment and warranty may be void.
CONTENTS
General Information ................................................... Page 1
Zone Controller Functions ......................................... Page 2
Turning Zone Controller On ....................................... Page 3
ESPAuto Mode ......................................................... Page 4
Zone Damper Blade Indicator .................................... Page 5
Fan Only Mode .......................................................... Page 6
Zone Temperature Display......................................... Page 8
Zone Open Mode ....................................................... Page 10
Trouble Shooting ....................................................... Page 11
Frequently Asked Questions ...................................... Page 12

3
ZONE CONTROLLER FUNCTIONS
Zone Indicator
ESP Auto Indicator
Illuminates when zone controller is
modulating the airflow.
OFF Indicator
Illuminates when zone is off and damper
is fully closed.
Set Temperature UP Button
Raises the set point for warmer
temperature.
Set Temperature DOWN Button
Lowers the set point for cooler
temperature.
Mode ON/OFF Button
Turn the zone ON or Off.
Room Temperature Button
View actual room temperature.
Damper Position Indicator
Indicates the position of of zones air
damper. (shown fully open damper)
COOL Indicator
Illuminates when zone is receiving
cooling.
HEAT Indicator
Illuminates when zone is receiving
heating.
Temperature Set Point Display
1
2
3
4
5
6
7
8
9
10
11
ROOM
TEMP
MODE
ON/OFF
SET
ZONE COOL HEAT
ESP
OFF
AUTO
C
TEMP
ZONE CONTROL
MAX
Zone Controller
11
10
8
7
6
9
5
4
3
2
1

4
TURNING ZONE CONTROLLER ON
Notes
* Zone Controller temperature setting can only be adjusted 2• 0C below or above
the Master Controller set point temperature. This is a factory set limit, which is
recommended in order to maintain system accuracy and maximize efficiency. Should
this require changing, contact ActronAir Technical support on freecall number :
1800 119 229
Master Controller shown above is LM7-D, same procedure applies with LM24W model.•
1Turn the system ON by pressing the button on Master
Controller LM7-D or LM24W.
2To turn the zone ON, press the button on Zone
Controller. Alternatively, press the designated zone on the
Master Wall Controller.
Zone Controller display will show the SET TEMPERATURE, ZONE and ESP AUTO.
3Set the desired temperature by pressing either the
SET TEMP UP / or DOWN / arrow key. *
For warmer room temperature, press the UP arrow key.• For cooler room temperature, press the DOWN arrow key.•
ON
OFF
MODE
ON/OFF
Master Wall Controller
FAN
AUTO
HEAT / COOL
AUTO
HEAT / COOL
LOW COOL
ON
OFF
PROGRAM
EXIT
SELECT
SET TEMP
SET TEMP
TIMER
REPEAT /
REPEAT /
RUMPUSFAMILY
BEDROOM 1
BEDROOM 1
KITCHEN DINING
MASTER BED
MASTER BED
BEDROOM 2
BEDROOM 2
BEDROOM 3
BEDROOM 3
2
1
3
3
ROOM
TEMP
MODE
ON/OFF
SET
ZONE COOL HEAT
ESP
OFF
AUTO
C
TEMP
ZONE CONTROL
MAX
Zone Controller
3
3
2

5
ESP AUTO MODE
Turning Off
3Press the button to turn off the zone. Alternatively,
press the designated zone button on the Master Controller.
When the designated zone LED in the Master Controller turns off,
the zone is off.
MODE
ON/OFF
Notes
In Zone Control ESPAUTO mode, the controller will adjust the position of zone• damper automatically in order to meet the desired temperature.
Heating mode will be displayed when the zone starts to heat the room.•
Cooling mode will be displayed when the zone starts to heat the room.•
1Press the button on until ESP AUTO appears
on the display.
2Set the desired temperature by pressing either the
SET TEMP UP / or DOWN / arrow key. *
For warmer room temperature, press the UP arrow key.• For cooler room temperature, press the DOWN arrow key.•
MODE
ON/OFF
ROOM
TEMP
MODE
ON/OFF
SET
ZONE COOL HEAT
ESP
OFF
AUTO
C
TEMP
ZONE CONTROL
MAX
Indications of COOL or HEAT will show
zone conditioning. (When zone damper is
providing warm or cold air to your zone).
Zone Controller
2
2
1
3
Master Wall Controller
FAN
AUTO
HEAT / COOL
AUTO
HEAT / COOL
LOW COOL
ON
OFF
PROGRAM
EXIT
SELECT
SET TEMP
SET TEMP
TIMER
REPEAT /
REPEAT /
RUMPUSFAMILY
BEDROOM 1
BEDROOM 1
KITCHEN DINING
MASTER BED
MASTER BED
BEDROOM 2
BEDROOM 2
BEDROOM 3
BEDROOM 3
3
2
2

6
ZONE DAMPER BLADE INDICATOR
DISPLAY STATUS
FULLY OPEN DAMPER BLADE
Allows full airflow through in order to meet your
required conditions.
PARTIALLY CLOSED DAMPER BLADE
Regulating airflow and temperature to
meet set conditions.
PARTIALLY OPEN DAMPER BLADE
Regulating airflow and temperature to
meet set conditions.
NO DAMPER BLADE INDICATOR
Room is satisfied with temperature.•Zone is turned off.•Zone is waiting on HEAT / COOL mode change.•
Note
When in ESPAUTO, damper blade indicator will automatically adjust itself to
regulate the correct amount of airflow (HEAT or COOL) in order to maintain the
desired setpoint temperature.

7
FAN ONLY MODE
1Ensure your air conditioner is turned off.
2Press the button. The current fan speed setting will
appear and the display backlight will turn on (if it is off).
3Press the button again to select HIGH, MED, LOW
fan speed.
4All open zones will circulate air throughout your home.
5If you wish to shut any particular zone in this mode, simply
turn off zone by pressing the designated zone button. Zone
LED will go off.
FAN
FAN
Notes
This mode is commonly used to circulate airflow without Cooling / Heating• throughout your home.
Quite often used on mild days to circulate fresh air through the home. Simply open•
a few windows and let the FAN ONLY MODE circulate fresh air through your home.
Master Wall Controller
FAN
AUTO
HEAT / COOL
AUTO
HEAT / COOL
LOW COOL
ON
OFF
PROGRAM
EXIT
SELECT
SET TEMP
SET TEMP
TIMER
REPEAT /
REPEAT /
RUMPUSFAMILY
BEDROOM 1
BEDROOM 1
KITCHEN DINING
MASTER BED
MASTER BED
BEDROOM 2
BEDROOM 2
BEDROOM 3
BEDROOM 3
3
2

8
FAN ONLY MODE
FAN MODE
will be displayed on zone control display when the Master Wall
Controller is set to circulation operation. During this period, zone damper will
be in fully open position for maximum air circulation.
Press the button to turn off the zone damper.
If you do not want the unit to circulate airflow in your room in this mode, simply
press the button in your zone controller or turn your zone OFF at the
Master Wall Controller
MODE
ON/OFF
MODE
ON/OFF
ROOM
TEMP
MODE
ON/OFF
SET
ZONE COOL HEAT
ESP
OFF
AUTO
C
TEMP
ZONE CONTROL
MAX
Zone Controller

9
ZONE TEMPERATURE DISPLAY
Notes
Room temperature displayed can be the temperature at a zone controller or at a
remote sensor or the average of both depending on your installation set up.
Average Room Temperature Display
1Press any of the buttons and the average room
temperature will be displayed for 3 seconds.
“INSIDE,” “0C” and “.” will be flashing. The temperature displayed is the average of
all activated zone sensors.
SELECT
Checking Individual Zone Temperatures
1Press any of the buttons.
2While “INSIDE,” “0C” and “.” are flashing, press the zone to
be checked.
“• INSIDE,” and “0C” will turn off. The selected zone LED and “.” flashes.
During this time, the selected zone temperature is displayed.•
3To check another zone, simply press the zone button while
the previous zone LED and “.” are flashing.
SELECT
TO CHECK TEMPERATURE AT MASTER WALL CONTROLLER
FAN
AUTO
HEAT / COOL
AUTO
HEAT / COOL
LOW COOL
ON
OFF
PROGRAM
EXIT
SELECT
SET TEMP
SET TEMP
TIMER
REPEAT /
REPEAT /
RUMPUSFAMILY
BEDROOM 1
BEDROOM 1
KITCHEN DINING
MASTER BED
MASTER BED
BEDROOM 2
BEDROOM 2
BEDROOM 3
BEDROOM 3
3
1
1
2

10
ZONE TEMPERATURE DISPLAY
TO CHECK TEMPERATURE AT ZONE CONTROLLER
Notes
To display the room/zone temperature for 45 minutes, press and hold button• for 5 seconds.
Press any button to exit.•
The room/zone temperature display can be the temperature at the zone controller or•
at a remote sensor or the average of both depending on your installation set up.
ROOM
TEMP
1Press the button.
Actual room/zone temperature will be displayed for several seconds then display
will return to setpoint temperature.
During this period, the blue LED on the button will flash indicating
the room temperature is shown on the display.
ROOM
TEMP
ROOM
TEMP
ROOM
TEMP
MODE
ON/OFF
SET
ZONE COOL HEAT
ESP
OFF
AUTO
C
TEMP
ZONE CONTROL
MAX
Zone Controller
1
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels ActronAir Panneau de contrôle