Actox ABD125KX Manuel utilisateur

ABD125KX User Manual
Page 1 of 34
ABD125KX / ABD125KXF
125 W Extended Ku-Band BUC
USER MANUAL

ABD125KX User Manual
Page 2 of 34
Table of contents
Introduction……………………………………………….……………..………...5
Receiving and
inspection…………………………………………………..…………………...…..6
Equipment Damage or Loss
Return of Equipment
Preparing for
installation…………………………………………………….…………..…….…..7
Safety Precautions
General
description………………………………………………..…………….……….…..8
Considerations
Securing the Block Up Converter
Installing the Block Up
Converter…………………………………………………………………………………….…………...9
LED Indicators, Connector Pin Assignment, 10MHz Reference
Powering Options, Setting L.O., Setting Tx/Rx Frequencies
Recommended Test
Equipment…………………………………………………………………….………………………...11
Assembly and
Installation………………………………………………………………….………12
Connections and Mounting Hardware
Functional
Overview………………………………………………………….………………..13
General
IF/RF Conversion and Amplification
Monitor and Control (optional)

ABD125KX User Manual
Page 3 of 34
Operation Procedure……………………………………….....………..….……...14
Maintenance……………………………………….………………….................15
Preventive Care
Procedure
Block Up Converter Cooling System Preventive Maintenance
Performance Check
Troubleshooting
Out-of Warranty Repair
Appendix 1 Technical
Specifications…………..………………………………….……...........…..…..17
Appendix 2 Mechanical
Drawing………………………………………….……………….…….…....….18
Appendix 3 Spare Parts………………………………………………….…….…..19
Appendix 4 M&C Commands ………………...…….…………………………..….….……..….20
Appendix 5 M&C Connection Instructions………………………………………....…………25

ABD125KX User Manual
Page 4 of 34
Scope
This document covers the installation, operation, and maintenance of the ABD125KX BUC. It contains
information intended for engineers, technicians and operators working with the block up converter.
To make inquiries, or to report errors of fact or omission in this document, please contact Actox Corporation
at toll free 866-888-6087.

ABD125KX User Manual
Page 5 of 34
INTRODUCTION
The ABD125KX is a reliable, high quality, cost efficient stand-alone block up converter. The application for
this block up converter is Ku-Band VSAT communication in an outdoor environment. This line of superior
products, engineered using state of the art technology, is characterized by unparalleled durability and
dependability.
This is the smallest and lightest 125W L-To Ku-Band Block Up Converter and is designed to be mounted on
the feed horn. The unit is ideal for portable and mobile applications.
KEY FEATURES
13.75-14.50 GHz
950 to 1,700 MHz
Smallest package size and weight
Double L.O. 12.80 and 13.05 GHz
Auto-ranging 80 - 240 VAC
Low power consumption (552W max)
Digital temperature compensation
L.O. lock and amplifier LED
M&C – combined RS-232/485,
Ethernet (HTTP and SNMP)
FSK
RoHS compliant

ABD125KX User Manual
Page 6 of 34
Receiving and Inspection
The block up converter is designed to function outdoors and will arrive in a standard shipping container.
Immediately upon receipt of the block up converter, check the packing slip against the actual equipment you
have received. Inspect the shipping containers exteriors for visible damage incurred during shipping.
CAUTION!
Handle the block up converter with extreme care. Excessive shock may damage block up
converter’s delicate internal components.
Using the supplied packing list, verify that all items have been received and undamaged during shipment.
Verify that all items are complete. If there are any omissions or evidence of improper packaging, please notify
Actox Corporation immediately.
Equipment Damage or Loss
Actox Corporation is not responsible for damage or loss of equipment during transit. For further
information, contact the responsible transport carrier.
When declaring equipment as damaged during transit, preserve the original shipping cartons to facilitate
inspection reporting.
Return of Equipment
When returning equipment to Actox Corporation for repair or replacement:
Identify, in writing, the condition of the equipment,
Refer to the Invoice, Purchase Order and the date the equipment was received.
Notify Actox Corporation RMA department of the equipment condition and obtain a Return Material
Authorization (RMA) number and shipping instructions.
NOTE
Do not return any equipment without an RMA number.
This is important for prompt, efficient handling of the
returned equipment and of the associated complaint.

ABD125KX User Manual
Page 7 of 34
Preparing for Installation
Before attempting to install or use the block up converter, we recommend that you first familiarize yourself
with the product by reading through this manual. Understanding the operation of the system will reduce the
possibility of incorrect installation, thereby causing damage or injury to yourself or others. The block up
converter must be installed in accordance with the conditions and recommendations contained in the following
sections.
Safety Precautions
Carelessness or mishandling of the block up converter may damage the unit causing serious injury to yourself
or others. Please adhere to the following:
WARNING!!
If your unit is equipped with an AC power cord and plug, do not tamper with, or attempt to
reconfigure, the cord or plug supplied with the unit, as this can:
Result in personal injury;
Void the warranty;
Cause damage to the units or related equipment.

ABD125KX User Manual
Page 8 of 34
INSTALLATION AND OVERVIEW
General Description
This section describes the installation and theory of operation of the block up converter.
ABD125KX is powered by +80~+240 VAC via IF cable or MS connector.
It will amplify an input signal from an L-Band RF source up to a power level of 125 Watts (min) CW in Ku-
Band.
The block up converter can be used as a stand-alone unit or in a redundant configuration.
Specifications
Table 1 summarizes the specifications of the ABD125KX BUC. For mechanical specifications, refer to the
outline drawing, Appendix 1.
General Considerations
The block up converter shall meet all specifications over full bandwidth and under all environmental
conditions when terminated with a load of VSWR at 2:1 unless otherwise specified. All RF specifications
shall be met within five minutes after applying power, except gain flatness, which shall be met after a warm-up
period of ten minutes. During the warm-up period, the block up converter shall not exhibit any alarm or
require an RF mute input signal to reset any alarm/fault latches.
Securing the block up converter
Align the block up converter output waveguide flange with the mating flange of the antenna feeder waveguide.
Using the O-ring and hardware provided, connect the antenna feeder waveguide. Torque the flange screws to
16 inch-pounds (1.8 N-m). Attach the proper cables for waveguide for IF input, AC power and M&C if
equipped to the corresponding connectors of the block up converter.
The cylindrical connectors are labeled clearly and have different pin layouts. It is impossible
to incorrectly install the mating connectors.

ABD125KX User Manual
Page 9 of 34
Installing the Block-Up Converter
Tools and Test Equipment
Have on hand a standard electrician's tool kit and any tools listed in the antenna
manufacturer's installation instructions.
Site Considerations
The BUC is designed to mount on the antenna. Locate and install the antenna according to
instructions supplied by the antenna manufacturer. Choose an area that is free of extraneous
interference from motors and electrical equipment and has a clear line of sight from the
antenna to the satellite. Lightning arrestors should be used at the site to protect personnel and
equipment.
Preparation
Mounting Considerations:
Optional Mounting Brackets are available that will facilitate mounting for most antennas.
The ODU must be mounted such that:
- Sufficient support is afforded to the BUC, the LNB and the Power supply to minimize the
effects of antenna sway in strong winds.
- Air movement across the heat fins is possible.
- The length of the Power supply cables is taken into consideration in determining the
mounting location of the power supply.
Throughout installation and during any polarization, azimuth or elevation adjustment, ensure
that cables and waveguide are not crimped or pinched.

ABD125KX User Manual
Page 10 of 34
SSPALEDGreenAllOK
SSPALEDRedSummaryAlarm
L.O.LEDGreenL.O.issetto13.05GHz
L.O.LEDGreenblinkingL.O.issetto12.80GHz
NOLEDindicatorsNOPOWER
10MHzLEDGreenExternal10MHzReference
10MHzLEDRed10MHzisAbsent
10MHzLEDGreenBlinkingInternal10MHzReference
10MHz Reference
The BUC must receive a stable external 10MHz reference provided by a stable signal source such as a signal generator,
satellite modem or injected externally with a Bias T (for example, ABT6ARN/ABT6ARF manufactured by Actox
Corporation) or a similar bias T type.
Please make sure to check the sticker on the BUC for the appropriate power source before any power
connections are performed.
LED Indication
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Actox Extenseur