ACL Staticide IONA TECH StatIQ Band Manuel utilisateur

1
© IONA Tech, LLC Document Version 1.1.0 7/10/2023
DISCLAIMER
Please read the following disclaimer carefully before using the StatIQ Band (the "Product"),
produced by IONA Tech (the “Company”). By using the Product, you (the “Customer”)
acknowledge and agree to the terms and conditions outlined below:
The Product is designed to help prevent electrostatic discharge damage in industrial
environments. However, it is important to note that the industrial environment is complex and
can involve numerous variables beyond our control. Therefore, the Company cannot
guarantee complete prevention of electrostatic discharge or damage to equipment or
systems.
The Product is provided "as is" and without any warranties, express or implied. The Company
makes no representations or warranties regarding the effectiveness or suitability of the
Product for any specic application or environment. It is the Customer’s responsibility to
assess and determine the appropriateness of the Product for their particular needs.
While the Product is designed to function under normal operating conditions, there may be
situations where it may fail to operate as intended without warning. This could result in
equipment damage, malfunction, or other adverse effects. The Company shall not be held
liable for any such damages or malfunctions.
It is crucial to follow all installation, operation, and maintenance instructions provided with the
Product. Failure to do so may result in improper functioning and potential damage to
equipment or systems. The Company shall not be responsible for any damage caused by
improper use, installation, or maintenance of the Product.
The Product is not intended to replace or substitute for any safety measures, protocols, or
regulations mandated by applicable laws or industry standards. The customer is responsible
for ensuring compliance with all relevant safety guidelines and regulations in your industry.
To the maximum extent permitted by law, the Company disclaims all liability for any direct,
indirect, incidental, consequential, special, or punitive damages arising out of or in connection
with the use or inability to use the Product, even if the Company has been advised of the
possibility of such damages.
The customer agrees to indemnify and hold the Company harmless from any claims,
damages, liabilities, costs, or expenses (including attorneys' fees) arising out of or in
connection with the use or misuse of the Product.
This disclaimer shall be governed by and construed in accordance with the laws of the state of
Colorado in the USA. Any legal action or proceeding arising out of or relating to this disclaimer
shall be brought exclusively in the courts of the state of Colorado in the USA.
By using the Product, the Customer acknowledges that they have read, understood, and
agreed to the terms and conditions of this disclaimer. If the Customer does not agree with any
part of this disclaimer, they should refrain from using the Product.
Distributed by ACL Staticide: +1-847-981-9212 Email: [email protected]

2
© IONA Tech, LLC Document Version 1.1.0 7/10/2023
StatIQ Band:
A Wearable Body Voltage Monitor
Table of Contents
Getting Started ................................................................................................................................................. 3
Operation..............................................................................................................................................................4
IONA Tech App.................................................................................................................................................. 7
Usage Details.................................................................................................................................................... 10
Troubleshooting..............................................................................................................................................15
Applications....................................................................................................................................................... 18
Technical Specications .............................................................................................................................19
Warranty Information ................................................................................................................................ 20
Regulatory and Safety Notices...............................................................................................................21
Get in Touch ..................................................................................................................................................... 24
Distributed by ACL Staticide: +1-847-981-9212 Email: [email protected]

3
© IONA Tech, LLC Document Version 1.1.0 7/10/2023
Getting Started
In the StatIQ Band box you will nd
•The StatIQ Band, with hook-and-loop arm strap
•A Zero Disc for rapid, one-handed zeroing of the StatIQ Band
•A USB-C charging cable
•A Quickstart Guide
•A Calibration Certicate for your StatIQ Band
Charging
Before you begin using the StatIQ Band, make sure the battery is fully charged. To
charge the battery:
1. Locate the USB-C charging port on the bottom edge of the device.
2. Plug the provided charging cable into any USB power source.
3. While charging, the Charging LED will be amber.
4. When the Band is fully charged, the charging LED will turn green.
5. The Band may take as long as an hour to charge, if completely at.
6. The battery life of the Band in use is 12-16 hours.
Sensor Protection
On delivery, the sensor will be
covered by a removable sticker.
Take this sticker off before
using the device. Do not stick
your ngers or other objects
into the sensor port, ever.
Doing so may lead to damage
or contamination of the sensor,
which is not covered under the
warranty.
Distributed by ACL Staticide: +1-847-981-9212 Email: [email protected]

4
© IONA Tech, LLC Document Version 1.1.0 7/10/2023
Operation
These pictures show the arrangement of the Band’s indicators and button.
Wearing the StatIQ Band
Secure the StatIQ Band around your upper arm in the orientation shown, ensuring
that the sensor is unobscured and pointed away from your body. The band should
be as high up your arm as possible.
Make sure to wear conductive or static
dissipative clothing such as an ESD rated
smock. Synthetic clothing will hold localized
charge that results in an offset in the voltage
measurement and undetected ESD events.
Ensure that you can see the three LEDs on the
upper edge of the device (the Mode, Body
Voltage and Bluetooth LEDs), and that the gold
sensor is situated above the Power/ Mode
button and the IONA logo.
Fasten the hook-and-loop strap just tightly
enough that the Band does not slip down your
arm, but not so tight as to be uncomfortable.
You may need to stretch your sleeve towards your hand before tightening the strap,
to ensure there are no folds of clothing covering the sensor.
Device ID
Power/Mode
Button
Charging
LED
Sensor
Ground Point
Socket
USB C
Connector
Bluetooth
LED
Power &
Mode LEDs
Body Voltage
LED
Distributed by ACL Staticide: +1-847-981-9212 Email: [email protected]

5
© IONA Tech, LLC Document Version 1.1.0 7/10/2023
Turning the StatIQ Band ON
Hold the Power/Mode button until the StatIQ Band turns ON. A similar press will
turn the StatIQ Band OFF.
The eld mill sensor will begin spinning and the device is now measuring the local
electric eld. If secured to your arm, this measurement represents an accurate
measure of your body voltage.
The Body Voltage LED indicates whether you are charged positive (red) or negative
(blue) and its brightness indicates the measured voltage relative to the alarm
threshold (discussed later).
Body voltage LED:
Red = Positive body voltage. Voltage below threshold
Blue = Negative body voltage. Voltage below threshold
Changing Alarm Modes
A short press of the Power/Mode Button will switch the band between the Muted
and Audible modes.
Power/Mode LED:
Yellow = device muted.
Green = audible alarms enabled.
The Power/Mode LED is visible both on the top edge of the StatIQ Band as well as
on the lid next to the Power/Mode Button.
Audible Alarms
Constant alarm = body voltage past threshold (only if audible alarms enabled)
Three quick beeps = ESD event detected (only if audible alarms and ESD Event
Detection enabled).
Single beep with Orange Power/Mode LED ash = low battery.
Four beeps with Red Power/Mode LED ash = empty battery, device powers off.
Continuous quick beeps with Red Power/Mode LED ash = shutter malfunction
(see Troubleshooting section).
Distributed by ACL Staticide: +1-847-981-9212 Email: [email protected]

6
© IONA Tech, LLC Document Version 1.1.0 7/10/2023
Default Settings
The StatIQ Band is intended to be usable out of the box, with no conguration
necessary. It is calibrated and zeroed in production. The default settings are:
Audible Alarms – muted (to be changed by pushing the Power/Mode button)
Alarm Threshold – ±1000V
Alarm Volume – 50%
ESD Event Detection – Enabled
Distributed by ACL Staticide: +1-847-981-9212 Email: [email protected]

7
© IONA Tech, LLC Document Version 1.1.0 7/10/2023
IONA Tech App
Download the IONA Tech App from the App Store or
Google Play Store to visualize the measured voltage data,
change device parameters, and more.
Pairing a Device
When you start the app, the following screen appears.
Select the Device that matches the address printed on
the label on the side of your StatIQ Band.
Note that when a device is paired with one app, it
cannot at the same time pair with another app on
another phone or PC.
The Bluetooth LED on the top edge of the StatIQ Band
will illuminate blue when the device is connected to an
app.
StatIQ Band paired with app
Distributed by ACL Staticide: +1-847-981-9212 Email: [email protected]

8
© IONA Tech, LLC Document Version 1.1.0 7/10/2023
StatIQ Band Data
Once you have paired with a device, the app will display
a real time graph of the voltage and events from that
device.
ESD Events will display on the graph as red dots, where
the position on the y-axis represents the voltage
change of the discharge.
Change the time scale above the graph to assess
various lengths of voltage data.
Select ‘Record Session’ to generate a CSV le of the
voltage and ESD data from the session. The le will be
generated in the Documents folder of your phone:
1. When you press ‘Save Recording’
2. If you close the connection by returning to the
Device List screen
3. If the connection is lost because the StatIQ Band
is turned off or if it goes out of range.
Device Conguration
Select the Gear icon on the previous page to adjust the
following options:
1. Voltage Threshold – the body voltage at which
the alarm will sound (the level is the same for
positive and negative voltage deviations).
2. Alarms Audible – checking this box changes the
device mode from Muted to Audible. The mode
can still also be changed by the Power/Mode
button on the device.
3. Alarm Volume – adjusts the alarm volume.
4. ESD Event Detection – checking this box
ensures that the StatIQ Band detects ESD
discharge events. Note that an audible alarm will
sound for ESD events only if Alarms are set to
Audible.
Record Session
Distributed by ACL Staticide: +1-847-981-9212 Email: [email protected]

9
© IONA Tech, LLC Document Version 1.1.0 7/10/2023
Unpairing a Device
Note that the Band will remain paired with the app, even if that app is not open on
the home screen of the phone. The Band can be unpaired by clicking “change
device” or pressing the back arrow from the voltage screen. A conrmation dialog
will appear before the connection is closed.
IONA Tech Browser App
All the functionality of the mobile apps can be achieved on a Chrome browser from
any computer equipped with a Bluetooth radio. Simply direct your Chrome browser
to:
https://app.iona.tech/
Distributed by ACL Staticide: +1-847-981-9212 Email: [email protected]
Table des matières
Manuels Électricité industrielle populaires d'autres marques

Murata
Murata GJM0335C1E4R4BB01 Series Manuel utilisateur

Stahl
Stahl 8575/12 Manuel utilisateur

SI
SI Pegasus Manuel utilisateur

Murata
Murata GRM1555C1H2R7CA01 Seies Manuel utilisateur

Murata
Murata GRM0225C1E6R4BA03 Series Manuel utilisateur

Cooper Power Systems
Cooper Power Systems VXE15 Manuel utilisateur

S&C
S&C Vista SD Manuel utilisateur

Murata
Murata GRM0335C2A7R3CA01 Series Manuel utilisateur

Siemens
Siemens 3VA9988-0BM10 Manuel utilisateur

Siemens
Siemens SITRANS LVS100 Manuel utilisateur

Murata
Murata GRM32ER60G227ME05 Series Manuel utilisateur

Siemens
Siemens SENTRON SUPERSWITCH 3KL82 Series Manuel utilisateur