Absolute Ozone NANO 15 Manuel utilisateur

1
NANONANO®®ATLASATLAS®®TITANTITAN®®MAGNUMMAGNUM®®
OZONE GENERATOROZONE GENERATOR
Operator’s Manual
CONTACT
Address
10712-181 ST NW
Edmonton, Alberta,
Canada T5S1K8
Phone & Email
Ph: (+1) 780-486-3761
Toll Free: 1-800-488-8565
E: of[email protected]

2
TABLE OF CONTENTS
Section 1 General Information
1A. Description
1B.Specications
1C. Accessories
1C.iOzoneGeneration
1C.ii Required Accessories
Section 2 Installation
2A.Location
2B.Electrical
2C. Plumbing
2D.GasConnections
2E. Remote Control
Section 3 Operation
3A.LCDControlPanelOverview
3B.SystemStartup
3C.SystemShutdown
3D.StandardOperatingProcedures
Section 4 Maintenance and Service
4A.PreventativeMaintenance
4B. Troubleshooting
Section 5 Ozone Overview and Safety Procedures
5A.InformacionGeneral
5A.iFuerzarelativadelozono
5A.iiMicro-oculaciónyoxidación
5B.Informacióngeneraldeseguridad
5B.iPropiedadesdelozono
5B.ii Usos del ozono
4
5
6
7
7
7
21
21
21
21
22
22
22
10
10
11
11
12
12
14
14
16
17
17
18
18
18

3
TABLE OF CONTENTS
5C.Hazards
5C.iHealthHazardsDetection
5C.iiHealthHazardsEffectsonHumans
5C.iiiElectricalHazards
5C.ivFireHazards
5C.vChemicalAction
5D.PrecautionsforSafeHandlingandUse
5D.iOzoneMonitors
5D.iiVentilation
5D.iii Emergency Procedure
5D.ivRespirationProtection
5D.vEducationandTraining
5E.SystemOperationsandMaintenance
5E.iSafetyPrecautionsandEquipment
5E.iiMaintenanceRequirements
5F.MonitoringEquipmentandlocation
5G. First Aid Procedures
5G.iGeneralInformation
5G.iiInhalation
5G.iiiEyeContact
5G.ivPrecautions
5G.vEmergencyInformationForm
Section 6 Ozone Limited Warranty
Section 7 Dimensions
23
23
23
24
24
24
28
28
28
28
29
29
25
25
25
25
25
26
27
27
27
27
30
32

4
SECTION 1 GENERAL INFORMATION
IMPORTANT SAFETY INSTRUCTIONS - PLEASE READ
CAREFULLY BELOW AND FOLLOW ALL INSTRUCTIONS
Read this manual completely before the operation
WARNING: High voltage is present inside the enclosure
USE EXTREME CAUTION
• Operatethegeneratorwithsafeaccesstoelectricalpower
• ConnecttoaGFCItypereceptacle
• Followallapplicableelectricalcodes
• Do not bury chord
WARNING: To reduce the risk of electrical shock, please
ensure to replace the damaged electrical chord immediately
ELECTRICAL SHOCK HAZARD: Turn OFF all the power
switches and disconnect the power chord from the power
source receptacle before performing any service work.
Failure to do so could result in serious injury or death
AbsoluteOzone®ozonegeneratorcelldesignisbasedon
proprietary Microfluidic Platform technology, constructed
from ozone-resistant materials, and offers extremely high
performanceandreliability.Theozonecellisdesignedto
beabsolutelymaintenanceandservice-free,theanticipated
servicelifeis15-20years.

5
SECTION 1 GENERAL INFORMATION
1A. Description
AbsoluteOzone®aremodulargeneratorsthatcanbeas-
sembled into systems from 15 g/h to up to 5 kg/h ozone
production.Atlas30UHCproduces23g/hofozoneata
concentrationofupto23%byweightorasspeciedinthe
performancetestreportsuppliedwitheveryunit.Absolute
Ozone®Ozonegeneratorsaredesignedtoproduceozone
foravarietyofapplicationssuchas,butnotlimitedto:
• WaterDisinfectionforBottledWaterPlants,Medical&
PharmaceuticalFacilities,SwimmingPools,etc.
• IndustrialProcesses,Chemicalproduction,Laboratories,
ElectronicProduction,Mining,etc.
• AquaticLifeSupportSystemsforMarineMammals,Fish
Hatcheries,andLargeAquarium.
• FoodProcessing,FoodProcessingFacilitiesDisinfection,
FoodPreservation.
• SoilRemediation,GroundWaterRemediation.
• WineriesFacilitiesDisinfection,BarrelDisinfection.
• CoolingTowersWaterTreatment,TechnologicalProcess-
esWaterTreatment.
• PotableWaterDisinfectionforSmallCommunities.
• WasteWaterTreatmentforIndustrialPlants,Technolog-
icalProductionProcesses,CommercialFacilitiesWaste
WaterTreatment,DangerouschemicalandBacteria
Treatment,etc.

6
1B. Specications
SECTION 1 GENERAL INFORMATION
MODEL OZONE
PROD.
(G/H)
WORKING
PRESS.
(PSIG)
OZONE
CONC.
(% W/W)
POWER
OPTIONS
NANO 15 15 20 5-10
120V~3%,50/60Hz,5.0A
220V~3%,50/60Hz,3.5A
Max.PowerCons:200W
ATLAS30/
TITAN30 30
20
9-12
120V~3%,50/60Hz,5.0A
220V~3%,50/60Hz,3.5A
Max.PowerCons:220W
ATLAS30C/
TITAN30C 30 9-16
ATLAS30UHC/
TITAN30UHC 23 9-22
ATLAS60
TITAN60 60 25-40 6-12
120V~3%,50/60Hz,8.0A
220V~3%,50/60Hz,6.0A
Max.PowerCons:550W
ATLAS80
TITAN80 80 25-40 5-12 120V~3%,50/60Hz,9.0A
220V~3%,50/60Hz,7.0A
Max.PowerCons:650W
ATLAS100
TITAN100 100 30-50 5-12
208V~3%,50/60Hz,
ThreePhase,5.0A
Max.PowerCons:950W
MAGNUM160 160 30-50 6-12
208/210/220/230V~3%,
50/60Hz,ThreePhase,
10.0A
Max.PowerCons:1600W
MAGNUM200 200 30-50 6-12
208/210/220/230V~3%,
50/60Hz,ThreePhase,
10.0A
Max.PowerCons:1700W
1C. Accessories
AbsoluteOzone®ozonegeneratorscouldbeusedwithsever-
alaccessoriesandsafetydevicestoensurealongservicelife
oftheozonegenerator.

7
SECTION 1 GENERAL INFORMATION
1C.i Ozone Generation
• Air Compressor:Theaircompressorpumpsambientpres-
surizedairintotheoxygengenerator/concentrator
• Oxygen Generator/Concentrator:separatesOxygenfrom
Nitrogenandsuppliesitdirectlyintotheozonegenerating
cellinsidetheozonegenerator
1C.ii Required Equipment and Accessories
• Oxygen Generator/Concentrator: The oxygen generator
usesaPSA(pressureswingabsorption)molecularsievebed
toremovedirt,moisture,nitrogen,andothertracegases,
producingoxygenatgreaterthan90%purityandlessthan
-60˚Cdewpoint.Theaircompressorpumpsambientairinto
the oxygen generator input. Then, the oxygen generator
outputsoxygen(O2)feedgasintotheozonegeneratorcell
andenablestheozonegeneratortoproduceozoneeffec-
tively at 6 to 23%wt. ozone concentration, depending on
oxygenow,andgeneratortype.Inourexperience,oxygen
generatorsmanufacturedbyAirSepworkverywellwithAb-
soluteOzone®ozonegenerators.
• Oxygen Filter: To protect the Absolute Ozone®generator
fromsieveparticlesincaseofoxygengeneratorfailureor
malfunction,werecommendinstallinganoxygenlterafter
theoxygengeneratorandbeforetheozonegenerator

8
1C.ii Required Equipment and Accessories
• Ozone Flow Control Valve (Flow Meter): This should be
installed downstream from (after) the ozone generator to
maintainworkingpressureacrosstheozonecellasspecied
fortheoptimalperformance.
• ALD 2000 Flood Prevention Device:Werecommendinstall-
inganALD2000witheveryozonesystemtreatingwaterto
prevent water from backing up into the ozone generator
anddamagingit.Non-return(checkvalves)donotprovide
100% water ooding protection to the ozone generator -
WE RECOMMEND installing the ozone generator WITH
theALD2000orsimilardevicewhentreatingliquids.
SECTION 1 GENERAL INFORMATION

9
SECTION 1 GENERAL INFORMATION
1C.ii Required Equipment and Accessories
Ozone Injector for Water Treatment Applications (Venturi):
Inletwaterowsthroughthepumpandtheozoneinjector,cre-
atinga vacuumthat pullsozonegas fromthe ozonegenera-
torandinjectstheozonegasintothewaterow.Theinjector
shouldbesizedtodissolveaminimumof90%oftheozonegas
intothewaterowcontinuously.
Ozone De-gas Tank:Ozoneenrichedwaterfromtheozonein-
jectorowsintothedegaschamber/tankwhereaslowdownof
waterowby2minallowsanyundissolvedozoneandoxygen
gastorisetothetopandbeventedthroughableed-offvalve
ALD2000Rtooutsideorthroughanozonedestructor.
Ozone Destructor:Undissolvedozonegaspassesthroughthe
regular or heated catalytic ozone destructor that is made up
of non-consumable manganese dioxide (heat-protected from
moisture fouling in heated destructor). The manganese diox-
ideoffersredundantozonedestructcapabilitiesifselectedand
sized correctly.

10
SECTION 2 INSTALLATION
2A. Location
OzoneGeneratorinstallationshouldallowforgoodaccessto
properelectricalpowerandrequiredgasconnectionsandallow
goodcoolingaircirculationfortheOzoneGenerator(s).
DO NOT OBSTRUCT COOLING AIR VENTS ON THE OZONE
GENERATOR.
The Absolute Ozone® generators must be installed in a
drycoolspaceprotectedfromweatherelements.Ambient
workingtemperaturefrom-10Cto+30C.
TheATLAS/MAGNUM® OzoneGeneratorshaveauniversal
mountingdesigntobeinstalledonaverticalwall,onahor-
izontalortiltedbench,mobilecartorskied.TITAN®enclo-
sureisdesignedfora19”electronicmountrack.
Reversible Universal Control Panel
ControlPanel
InUpright(For
BenchmountInstal-
lations)Position
Remove4Screws
andReversethe
ControlPanel180
DegreestoDown-
right(ForWall
MountInstallations)
Position*
TightenScrews NowtheATLAS/
MagnumcanbeIn-
stalledinWallMount
Position
*PleasebecarefultonotdisconnectLCDwireswhenreversingcontrolpanel