AAON CommLink 5 Guide de démarrage rapide

CommLink 5
Technical Guide

TABLE OF CONTENTS
GENERAL INFORMATION.............................................................................................................. 3
CommLink 5 Overview ............................................................................................................................................. 3
Optional IP Module Kit ............................................................................................................................................. 3
Installing CommLink 5 ONLY ................................................................................................................................... 3
System Requirements .............................................................................................................................................. 3
QUICK START GUIDE .................................................................................................................... 4
CONNECTIONS & WIRING............................................................................................................. 5
LOOP COMMUNICATION SETTING............................................................................................... 6
BAUD RATE SETTING.................................................................................................................... 7
USB DRIVER INSTALLATION INSTRUCTIONS ........................................................................... 8
FINDING THE COM PORT NUMBER.............................................................................................. 9
PRISM 2 SETUP INSTRUCTIONS................................................................................................ 10
TROUBLESHOOTING................................................................................................................... 12
CommLink 5 LED Descriptions .............................................................................................................................. 12
Connecting the Network - Proxy and Firewall Compatibility .................................................................................. 13
Troubleshooting Tips .............................................................................................................................................. 14
Changing the USB Serial COM Port Number ........................................................................................................ 15
www.aaon.com
AAON, Inc.
2425 South Yukon Ave.
Tulsa, OK 74107-2728
www.aaon.com
Factory Technical Support Phone: 918-382-6450
Controls Support Phone: 866-918-1100
AAON P/N: G015590, Rev 01K
Copyright August 2019 AAON, Inc.
AAON, Inc. assumes no responsibility for errors or omissions.
This document is subject to change without notice.
Windows® 10 is a registered trademark of Microsoft Corporation.
This manual is also available for download from our
website—www.aaon.com/communicationdevices—
where you can always find the latest literature updates.

OVERVIEW
3
CommLink 5 Technical Guide
CommLink 5 Overview
The ASM01874 CommLink 5 is used to transfer communications
between controllers or local loops on your control system. It can also
be used as an interface for connection of a computer to your system.
The CommLink 5 provides communication with the control system
through any computer that is running Prism 2 software. For remote
communications, an IP Module Kit can be installed for LAN and
Internet connections.
Optional IP Module Kit
The ASM01902 IP Module Kit, when installed and confi gured in
the CommLink 5 communication interface, provides TCP IP Inter-
net and/or intranet connection for Ethernet networked computer
systems, allowing them to communicate with your control system.
The IP Module Kit consists of the IP Module and a 10 ft. long CAT5
Ethernet crossover cable.
Using standard TCP/IP Protocol, with AAON’s Prism 2 software, you
are able to monitor and confi gure your controllers without a modem
or a direct connection from a PC. Utilizing existing routers, proxies,
or fi rewalls allows a PC running Prism 2 to connect to a controller
in a remote accessible location or building. Several IP connection
profi les can be created to facilitate monitoring several CommLink
5’s with IP Module Kits installed on individual sites.
Installing the CommLink 5 ONLY
When you are using the CommLink 5 in an application without a
computer or IP Module, follow Steps 1-3 in the Quick Guide on
page 4.
WARNING: If you are replacing an earlier version of the Com-
mLink with a CommLink 5, be aware that the R(+) and T(-)
terminals on the communications terminal block are reversed
from all previous models of the CommLink. You must always
confi rm that the polarity is correct when wiring 24 VAC power
to the CommLink power terminal block or serious damage to
the product will result.
System Requirements
To program the CommLink 5 to work with Prism 2, you will need:
Standard Items (Required)
• CommLink 5 with USB cable and power adapter (supplied)
• A PC with an Ethernet communications port or USB
port (supplied by others)
• USB drivers on CD-ROM (supplied and also
downloadable from www.aaon.com/prism)
• Microsoft Windows® 10 (must be installed on the
computer you are going to use)
• Prism 2 software, version 4.0.3 and up (can be
downloaded for free from www.aaon.com/prism)
Optional Items
• IP Module Kit that comes with Ethernet RJ-45
Crossover CAT 5, 10 ft. long cable for LAN, and Internet
remote communications
• MiniLink, MiniLink PD, or MinkLink PD 5
NOTE: AAON Controls Support cannot troubleshoot inter-
nal PC and/or Windows®-based operating system
problems.
General Information

QUICK START GUIDE
CommLink 5 Technical Guide
4
Quick Start Guide
Quick Start Guide
Follow the fi ve steps below to get your CommLink up and running in
no time.
NOTE: If you are using the CommLink 5 without utilizing
Prism 2, you need only perform Steps 1-3.
Step 1: Set your CommLink’s Loop switch to Multiple or Single.
See Figure 2 on page 6.
Step 2: Set your CommLink’s Baud rate switch to High or Low.
See Figure 3 on page 7.
Step 3: Wire your CommLink to the appropriate controller on your
system, and plug the CommLink into a power supply. See
Figure 1 on page 5.
WARNING: If you are replacing an earlier version of the Com-
mLink with a CommLink 5, be aware that the R(+) and T(-)
terminals on the communications terminal block are reversed
from all previous models of the CommLink. You must always
confi rm that the polarity is correct when wiring 24 VAC power
to the CommLink power terminal block or serious damage to
the product will result.
Step 4: Install the USB drivers located on the included CD-ROM.
See instructions on page 8. Then attach one end of the USB
cable to the back of your CommLink and the other end into
your computer’s USB port.
Step 5: Install Prism 2 software on your computer. See instructions
on pages 10 & 11.
NOTE: For remote communication, follow the instructions
included in the IP Module Technical Guide.
IMPORTANT NOTES:
First install the USB drivers, then follow the included
CommLink 5 connection and wiring instructions sheet
(Figure 1 on page 5) to connect and confi gure the
CommLink 5.
Familiarize yourself with all system components and
review all documentation. Pay special attention to
“Cautions,” “Notes,” and “Warnings” since these may
keep you from experiencing unnecessary problems.
If you encounter any problems, please refer to the
Troubleshooting section of this guide fi rst. If you
can’t resolve the problem, please call AAON Controls
Support at our toll free number—1-866-918-1100.

CommLink 5 Technical Guide
CONNECTIONS & WIRING
5
Connections & Wiring
Figure 1: CommLink 5 Connection & Wiring

COMMUNICATION SETTINGS
CommLink 5 Technical Guide
6
Loop Communication Setting
Figure 2: Setting Loop Communications

CommLink 5 Technical Guide
COMMUNICATION SETTINGS
7
Baud Rate Setting
Figure 3: Setting the Baud Rate

USB DRIVER INSTALLATION
CommLink 5 Technical Guide
8
USB Driver Installation
The internal USB communication port of the CommLink uses a spe-
cialized driver that must be installed on your Windows® PC before
communication to the device can be established.
NOTE: You may already have this driver installed on your PC if
you have used or are using a USB-Link 2.
1. Before you begin, you must determine if your computer
is running 32-bit or 64-bit Windows. Open the System
information by right-clicking the <Start> button and
then clicking <System>. Under System, you can view
the system type. Based on what type of system you have,
you will choose 32_Bit.exe or 64_Bit.exe from the list of
fi les shown in Step 10.
2. Insert the USB Drivers CD-ROM into your CD-ROM
drive or download the USB Drivers fi le from www.
aaon.com/prism. If using the CD-ROM, go to Step 7. If
downloading the fi le, you will need to scroll down the
page until you fi nd “USB Drivers For All Products” to
download the driver fi les.
3. Right click on “Click Here.” Then click <Save Link
As> or <Save Target As> and select Desktop as the
destination.
4. Go to the “USB-DRIVERS-ALL.exe” fi le on your desk-
top. Double-click on this fi le and choose “Run” from the
options list. The following window will appear:
5. Select <Unzip> and the fi le will be unzipped to the
folder C:\Temp\WM-USB-Drivers folder by default.
6. Next, go to the C:\Temp\WM-USB-Drivers folder and
now go to Step 9.
7. Click your <Start> button and then click, <Computer>.
8. Double-click on your CD-ROM drive. Open the Media
Files Folder.
9. Double-click the folder “USBLink NewSS0073”.
10. The following list of fi les will display. Choose 32_Bit.
exe or 64_Bit.exe based on what type of system you
determined you have in Step 1.
11. In the window that pops up, shown below, click <Next>
and the installation program will walk you through the
rest of the steps.
12. When successful installation has occurred, connect the
USB cable between the PC and the USB-Link 2. The
PC will automatically recognize the device and a COM
port will be assigned. Follow the procedures on page 9 to
verify the Comm Port.
USB Driver Installation

CommLink 5 Technical Guide
USB DRIVER INSTALLATION
9
Finding What COM Port Number the
CommLink 5 is Using (Windows®10)
1. Right-click on the Windows® icon, located on the bottom
left or top left of the Windows Tool Bar.
2. Select <Device Manager>.
3. Click on the plus sign next to Ports to see all of the
common ports.
4. Locate the USB Serial Port (COM#). The COM# in
parentheses is the port it is located on. Write this COM
port number down. You will need to know this when
setting up the Prism 2 software.
5. If the COM port number is 10 or greater, go to “Chang-
ing the USB COM Port Number” in the Troubleshooting
section on page 15.
Finding the COM Port Number

PRISM 2 SETUP
CommLink 5 Technical Guide
10
8. In the Network Conguration selection box, select the
type of system conguration you are using. e only
options applicable to CommLink 5 are Multiple Loop
Conguration (Network) or Single Loop Conguration.
9. Click <Exit> to close out of the Job Sites Window.
10. Click the <OFFLINE> button to go
<ON LINE>.
11. From the <Communications> menu, select <Search
for Units>.
Prism 2 Setup Instructions
Prism 2 Setup
1. Open your Prism 2 soware.
2. Click the <Login> button and type in the
Level 9 User Name and password (default is
“admin, admin”). Click <Login>.
3. If Prism 2 is online, click the
<ON LINE> button to make it go
<OFFLINE>.
4. Click the <Job-Site> button to open the
Job-Sites Window.
5. Click on any empty location in the Job-Site Selection
Window and then type in a job name in the Selected
Location box and press <Enter>.
6. In the Serial Port eld, click on the pull down box and
select the COM Port number that the CommLink 5 is
using.
7. In the Type of CommLink selection box, select the radio
button next to CommLink 5.
Autres manuels pour CommLink 5
1
Table des matières
Manuels Système de conférence populaires d'autres marques

Kramer
Kramer VIA GO Manuel utilisateur

AVT
AVT MAGIC AC1 Go Manuel utilisateur

ProSoft Technology
ProSoft Technology AN-X4-AB-DHRIO Manuel utilisateur

Sony
Sony PCS-I150 Manuel utilisateur

Middle Atlantic Products
Middle Atlantic Products VTC Series Manuel utilisateur

Prentke Romich Company
Prentke Romich Company Vanguard Plus Mode d’emploi