A2Z Ozone MP-1000 Manuel utilisateur

MP-1000 (110V) Ozone Generator
Operating Manual
*Register your product at a2zozone.com/pages/warranty
Produced for and Distributed by:
A2Z Ozone, Inc
1844 Cargo Court.
Louisville, KY 40299 USA
1+502-499-4977
EPA Est.: 95432-KY-1
Active Ingredient: Ozone.
Warning: Do Not Inhale Ozone.
Keep Out of Reach of Children.
Produced by:
Bluegrass Water Technology
Shenzhen Co., Ltd.
Shenzhen, Guangdong
Made in China
EPA Est.: 95432-CHN-1
Version 1.2.2

1
Table of Contents
Important Safety Information .............................................................................. 2
Technical Specifications ........................................................................................ 3
Features ................................................................................................................... 4
Timer Functions .................................................................................................... 6
Installation Instructions ....................................................................................... 7
Operating Instructions ......................................................................................... 8
Maintenance ..........................................................................................................11
Troubleshooting ....................................................................................................12
Warranty ................................................................................................................15
WARNING: Do Not Inhale Ozone. Ozone Can Damage Lungs if Inhaled. Remove
Immediately to Fresh Air if exposed. Keep Out of Reach of Children. Hazards to
Humans and Domestic Animals--Do Not Expose Children, People, Pets, Plants or
Valuables to Ozone. Ozone Health lnformation--lf exposed to ozone, get to fresh
air immediately. Seek doctor's advice if exposed to ozone.
WARNING: The use of a degasier and an ozone destructor is necessary to ensure
excessive ozone is safely removed from the application. Leave the area while the
application is in operation. In case of accidental leakage, keep the Ozone generator
in a well-ventilated area. NOTE: The water tank requires an exhaust to the outside
of the building with ozone destructor to remove excessive ozone.
HIGH VOLTAGE! Perform service on ozone generator by certied technicians only!
For your safety, do not store or use gasoline, chemicals or other ammable liquids
or vapors near this or any other appliance. NOTE: Use Only As Directed. Follow
All Instructions Provided in the Manual. Buyer will assume all responsibility for
installation, running and use not in accordance with direction.

2
Important Safety Information
READ AND FOLLOW ALL INSTRUCTIONS
• Follow all electrical codes.
• Turn power off and disconnect from power source before any service work is performed.
Failure to do so could result in serious injury or death.
• Electric shock hazard. Use the power cable provided to connect the MP-1000 to a properly
rated and grounded receptacle.
• If the MP-1000 will be used where water is present, a ground fault circuit interrupter must
protect the circuit.
PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
Use ozone test strips or dissolved ozone monitor to acquire your desired level of ozone.
CAUTION: In case of accidental leakage, install the
ozone generator in a well-ventilated area.
In accordance with California Regulations, this ozone
generator is solely for industrial use and must be
installed by a professional. Potential Health Hazard:
Emits Ozone.

3
Technical Specications
Model Ozone
Capacity
Oxygen
Feed Gas
Flow Rate
Dimensions Energy
Usage Concentration Unit
Weight
lbs/day g/hr LPM H x W x D V/W mg/L lbs KG
MP-1000 0.053 1 1 LPM of O2
or dry air 10.7 x 6 x 9 110V/45
16.7 @ 1.5 LPM
w/ O2input
2 w/ internal
pump
8.5 4
Items Included:
• MP-1000 (110V) ozone generator
• MP-1000 (110V) operation manual
• 8 feet of flexible tubing included
• Two 1” oblong diffuser stones included
• Spare fuse included
• Fan filter replacement

Features
1Ozone Light Indicates ozone is functioning. If the LED is illuminated, the unit is
working properly.
2Power Light Indicates when there is power to the unit. If the power is supplied, the
light will remain illuminated.
3O3Switch Used to control ozone power within the unit.
4Air Pump Switch
Used to power on the small internal air compressor built into each
MP Series unit. If using oxygen supply, DO NOT turn on air pump
switch.
5O3Out Port Ozone produced by the unit exits through this port.
6O2In Port Optional hook up port for an external oxygen source. This can be
used to produce a more pure form of ozone.
7Air Out Port Air port for the air compressor (loops into O2In Port for ambient air
use).
8Timer (Hour) Sets a time limit for the unit to produce ozone. The unit timer needs
to be engaged for ozone production.
9Ozone
Concentration
Knob
Controls the percentage of ozone produced by the unit.
4

5
1
2
3
4
5
6
7
8 9
MP-1000

6
Timer Functions
The MP-1000 (110V) Ozone Generator is equipped with timer functions. The hourly timer knob
can be adjusted between 15 minutes and 4 hours, at any time interval between.
• 15 minutes to 4 hours
• To operate this timer, turn the knob clockwise to the desired set position.

7
Installation Instructions
Ozone Generator Placement
• Install ozone generator in a clean, dry area with good ventilation.
• Place the MP-1000 (110V) Ozone Generator above any water tank level.
• If pressure is lost in the venturi injector vacuum and the unit is below water tank level, gravity
will cause water to travel down the ozone output hose and enter into the ozone generator.
• Place stone no more than 12 inches deep for the MP-1000.
NOTE: Place the ozone generator in room temperatures below 130° F , 54 ° C. Prolonged exposure
to extreme temperatures will void the warranty.
Venturi Injector Installation
• Install the venturi injector with the bypass valve on water recirculation pipeline.
• Set the arrow on venturi injector in the same direction as water flow.
• Turn water pump on and close the bypass valve until a vacuum is created at the venturi injector
input.
NOTE: Use a gauge to check vacuum -2 to -3 PSI (-0.14 to -0.21 bars) or place finger over end of
venturi injector valve to feel the vacuum. At this point, the air is injected into the water line. This
can be observed as air bubbles inside the water tank.
NOTE: The water tank requires an exhaust to the outside of the building
with an ozone destructor to remove excessive ozone.
Main Power
• Use the power cable provided to connect the MP-1000 to a properly rated and grounded
receptacle.
• If the MP-1000 will be used where water is present, a
ground fault circuit interrupter must protect the circuit.
• Plug your power cord into the back of the unit and the wall socket.

8
• Remove the bulkhead nut on O³out port.
• Then insert the bulkhead onto the tubing.
• Slide tubing onto the O³outlet barb.
• Screw the nut back onto the O³out port.
• Attach the diffuser stone of your choosing to the opposite end of the tubing or connect other
end to the venturi suction port.
NOTE: Be sure to set the unit above water level. A check valve can also help prevent water from
back-flowing into the unit.
For Oxygen Input:
• Disconnect the small tubing from the O²in port.
• Connect the oxygen source to the O²in port with appropriate tubing. You may use the provided
flexible tubing.
• Adjust the flow rate of the oxygen source to a maximum of 1-3 L/minute
NOTE: Ensure that the air compressor switch is in the OFF position when using an oxygen source.
For Ambient Air:
• Turn on both air compressor switch and the ozone switch, in that order.
• Keep in mind, the unit will NOT power up until the timer is set.
• Turn the power button on – it is located on the back of the unit by the power cord.
• Turn the ozone concentration knob to 100 percent or desired concentration for the given
application.
CAUTION: If ozone concentration is below 20 percent, the unit will not power up unless external
oxygen is attached. The dial can be adjusted after starting, but avoid dialing up and down
continually, as this action may harm the control board.
• Set the unit timer for the desired application duration.
• At this point, the MP-1000 is powered up.
To turn the unit off:
• For Ambient Air:
• Turn off the ozone switch.
• Wait 10 seconds before continuing.
• Turn off the air compressor switch.
• For Oxygen Air:
Operating Instructions

9
• Turn off the ozone switch
• Wait 10 seconds before continuing.
• Turn off the oxygen source.
Tube Connection and Start Up
An oxygen tank or oxygen generator can be used but is not required for ozone production.
Using Oxygen Bottle/Tank:
• Connect oxygen bottle/tank to ozone generator (Oxygen In Port).
• Connect MP-1000 Ozone Generator (Ozone Out Port) to venturi injector.
• Install a check valve 10 inches after ozone outlet tube fitting. This can be done by cutting a tube
ten inches after ozone outlet fitting.
• Connect both ends of cut tubes to the check valve. Please direct the arrow on the check valve
toward venturi injector.
• Set tank gas flow meter at 1-3 liters per minute and 3 PSI maximum.
• First, open the oxygen valve then only turn on the main ozone power switch on the front panel
of the MP unit (internal air compressor switch stays OFF). The ozone light and fan should turn
on.
• Increase power to the cells by turning the ozone concentration knob clockwise. Please remember
to make a full rotation clockwise.
• Prior to shutting off the feed gas to the unit, turn off the switch and allow the unit to purge for
about 1 minute.
• Then, turn the flow of oxygen gas off.
NOTE: Do not turn the air pump switch ON when using oxygen generator, oxygen bottle or tank.
Using Oxygen Generator:
• Connect oxygen generator (Oxygen Out Port) to ozone generator (O2In Port).
• Connect MP unit (Ozone Out Port) to the venturi injector.
• Install a check valve 10 inches after ozone outlet tube fitting. This can be done by cutting a tube
ten inches after ozone outlet fitting.
• Connect both ends of cut tubes to the check valve.
• Please direct the arrow on the check valve toward the venturi injector.
• Turn the oxygen generator ON first and then the ozone generator switches (the air pump stays
OFF).
• Turn timer knob clockwise to the amount of time needed.
• The ozone light and fan should turn on.
• Increase power to the cells by turning the ozone control knob clockwise.